INSTALLATION
The most desirable and beneficial location for a
YUNCA FUZiON
(Fuzzy Logic control) heater is in
the centre of a building, thereby allowing the most efficient use of the heat created.
The location of windows, doors and the traffic flow in the room where the heater is to be located,
should all be considered, as should availability of power supply to the fan boost.
If possible a location should be selected that allows the flue pipe to be installed simply and pass
through the house without cutting a floor or roof joist. Refer to page 5 for typical flue installation (Fig
2).
To obtain maximum heat distribution with any freestanding heater a ceiling fan may be fitted.
When the appropriate position has been selected the unit must be bolted to the floor to ensure that
the unit remains upright in the event of an earthquake or similar (Fig 1 below). If the heater is being
attached to a concrete floor dyna bolts should be used, if the floor is wooden the bolts used should
be long enough to go fully through the floorboards and fixed with nuts and washers from the
underside. The earthquake brackets are located at the front corners of the heater.
The
Yunca FUZiON
does not require a floor protector (hearth), and if desired can be placed directly
on to carpet or wooden flooring.