background image

Revised 03-11-10

 

 

 

 

YUNCA FUZiON FEBRUARY 2010 

 

 

Page 9 of 19 

FUZiON INFRA-RED REMOTE CONTROL with AUTO TIMER.

 

 

POWER ON / OFF: 

First check that the two AAA batteries are inserted. The remote may appear to 

be on, but it is likely that is not so. The remote control is protected with a “kiddy lock”. To turn it on 
press and hold the 

POWER

 button for about 2 seconds until “off” disappears from the screen, then 

release (to unlock the safety feature), and quickly give one short press of the 

POWER

 button. This  

will turn on power to the remote control, and will also start the fire in the MANUAL - HIGH setting. 
Current mode / settings will be displayed. The fire will always start in manual operating mode on a 
high setting. (Also refer to the next page for further information). There is an audible beep when the 
fire receives a signal from the remote, range is approximately 5 metres. 

 

CLOCK SETTING: 

Press the 

CLOCK

 button once (“clock” in the display will start flashing). Press 

WEEK

 to set the week day, press 

HOUR

 to set the hour, taking care to check if on a.m. or p.m. 

Press 

MIN 

to set the minute (holding the button down will advance the minutes quicker). Press 

CLOCK 

to save the setting. 

 

MANUAL “FLAME” OPERATING MODE

 has three settings: High, Medium, Low. Heat output is 

fixed to the setting and needs to be adjusted manually by pressing 

TEMP

 control “ – “ and “ + “ 

buttons. 
 

“FUZZY LOGIC” OPERATING MODE 

replaces the traditional thermostat operation with six “comfort 

levels”. Press 

MODE

 to switch between 

Manual

 and 

Fuzzy Logic

, and use the 

TEMP

 “ 

 “ and “

 +

 “ 

buttons. Choose the comfort level that best suits your needs. Every now and then the fire will give a 
short boost of heat and then return to your chosen setting. This is the most economical way to 
operate your Yunca Fuzzy Logic control fire. 

 

HINT

:  The  two  speed  fan  is  designed  to  quickly  transfer  heat  around  the  room  and  ensures  the  most 

economic gas use. The three-position switch (LOW/OFF/HIGH) is located under the front hearth panel, to the 
right of the manual control. 
 

AUTO FUNCTION

To set this feature you will need to ensure the remote control is on (as advised above), 

and ensure the 

CLOCK

 time and day are correctly set. 

PLEASE NOTE:

 If a key is not pressed for 7 seconds, 

the programming will “time out” and you will need to re-start the process. 
 
Set times to Start and/or Stop the fire with a choice of up to two daily programme settings (

PROG1

 and 

PROG2

). You can choose to use only 

PROG1

 if only one setting is needed. Heat output on Auto is initially run 

in manual control, and once the fire is operating you can then switch to the more economical Fuzzy Logic. 

 

EXAMPLE

: Set 

PROG1

 to start at 6:00 am, stop at 8.00am. Set 

PROG2

 to start at 4.30pm, stop at 10.30pm 

Monday to Friday. Both 

PROG1 

and

 PROG2 

may have different settings programmed for the weekend if 

required. 
 

TO SET: 

Press 

PROG1 

to set the “timer on” setting (Mon-Fri). Now choose the desired heat output (High, 

Med or Low) Press 

HOUR

 button, making sure you have chosen the correct a.m. or p.m. time, then press 

MIN

 button (increases in 10 minute steps) to set the start time. Press 

PROG1

 again and use the 

HOUR

 / 

MIN

 

buttons to set the stop time. Press 

CANCEL

 at any time to clear the setting currently on screen (i.e.either 

Start or Stop). If you are not setting weekend programming, just press 

PROG1 

to save your settings and exit 

the programming function. 
 
If you wish 

PROG1

 to operate on Saturday and Sunday, press 

WEEK

 button to set start time, using 

HOUR

 

and 

MIN

 buttons as described above. Then press 

PROG1 

again to set the weekend stop time, and press 

PROG1 

once more

 

to save your settings and exit the setting mode. 

 

 

Continue as above using 

PROG2

 if required. To check the programme settings press either Prog1 or Prog2. 

 

…Important Info 

continued on page 10… 

Summary of Contents for Fuzion

Page 1: ... FEBRUARY 2010 Page 1 of 19 FUZiON FUZZY LOGIC control FREESTANDING GAS HEATER FEBRUARY 2010 INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION These instructions should be stored in a convenient safe place for ready reference ...

Page 2: ...TROL AUTO TIMER 8 10 MANUAL CONTROL OPERATION 11 MAINTENANCE 11 16 DOOR REMOVAL GLASS REPLACEMENT 11 GLASS CLEANING DOOR ROPE REPLACEMENT 12 BATTERY BACK UP 12 SERVICE INSPECTION AND CLEANING 13 GAS CONTROL VALVE CONNECTIONS 13 FAN REMOVAL 14 TROUBLE SHOOTING GUIDE 15 16 Appendix A PARTS LIST 17 Appendix B INJECTOR SIZES 17 Appendix C WARRANTY 18 Appendix D WIRING DIAGRAM 18 Appendix E WARRANTY RE...

Page 3: ...eature kiddy lock controls for added peace of mind We highly recommend the use of the two speed fan boost on the fire for greater heating efficiency Should power not be available for any reason battery back up through two D sized batteries ensures the fire will continue to operate without the fan boost Ref page 12 The installation of the YUNCA FUZiON Fuzzy Logic control FLUED GAS HEATER must be ca...

Page 4: ...loor or roof joist Refer to page 5 for typical flue installation Fig 2 To obtain maximum heat distribution with any freestanding heater a ceiling fan may be fitted When the appropriate position has been selected the unit must be bolted to the floor to ensure that the unit remains upright in the event of an earthquake or similar Fig 1 below If the heater is being attached to a concrete floor dyna b...

Page 5: ...Revised 03 11 10 YUNCA FUZiON FEBRUARY 2010 Page 5 of 19 Fig 2 ...

Page 6: ... below Fig 3 and comply with NZS 5261 AG601 This is to ensure adequate air circulation around the heater and avoid heat damage to wall coverings Note If walled surface is non combustible i e brick or steel side clearances may be reduced to 100mm however note that this may severely restrict access to the appliance for servicing Corner positions and back clearance remains the same See Fig 3 Below Fi...

Page 7: ...ECK GAS PRESSURE 1 Remove door assembly refer page 11 2 Remove front hearth and control panel assembly Three screws hold the hearth and two screws hold the control panel locked under sides 3 Test point can be seen on the left side of the control box 4 Slacken test point screw and check pressures 5 Re tighten test point screw GAS PRESSURE REQUIREMENTS Correct gas pressure and the use of a properly ...

Page 8: ...Revised 03 11 10 YUNCA FUZiON FEBRUARY 2010 Page 8 of 19 FUZiON INFRA RED REMOTE CONTROL with AUTO TIMER N B DO NOT LEAVE THE REMOTE CONTROL ON TOP OF YOUR FIRE ...

Page 9: ... two speed fan is designed to quickly transfer heat around the room and ensures the most economic gas use The three position switch LOW OFF HIGH is located under the front hearth panel to the right of the manual control AUTO FUNCTION To set this feature you will need to ensure the remote control is on as advised above and ensure the CLOCK time and day are correctly set PLEASE NOTE If a key is not ...

Page 10: ...u will see the AUTO symbol display on the LCD screen of the remote control unit IMPORTANT Press AUTO SET button again to cancel the auto feature or the fire will continue to operate to the automatic settings even if the remote is off NOTE Even when AUTO SET is activated i e the display shows AUTO on the remote and the green light on the fire is flashing you can continue to operate the fire i e tur...

Page 11: ...REMOVING THE GLASS FOR REPLACEMENT 1 Remove the front door as described above and place front down on a soft surface 2 Remove the screws around the perimeter of the inner door and lift clear 3 The glass and old thermotape seal can be lifted clear and discarded 4 New glass 1610BX and thermotape seal 1611BX can be ordered through your YUNCA agent Note Only recommended heat resistant glass may be fit...

Page 12: ...2 Remove the existing gasket and clean the channel of all loose material 3 Lay the gasket in the channel ensuring the gasket is not stretched 4 Replace the door carefully to avoid dislodging the gasket BATTERY BACK UP REPLACEMENT Your YUNCA GAS FUZiON Fuzzy Logic control will operate WITHOUT FAN BOOST if power is not available for any reason Two D size batteries are located under the front hearth ...

Page 13: ...paper and carefully place it out of the way 3 The bark tray can be removed by undoing the attachment screws and lifting out 4 With firebox empty a vacuum cleaner can be used to remove any visible dust and lint from within the firebox area 5 Replace the bark tray 6 Replace log set 7 Replace the front door CLEANING UNDER THE TOP AND LOUVRES Two screws at the back and two lugs at the front hold the t...

Page 14: ...Main Power first 1 Remove the Door and Top Louvre see page 11 2 Remove 3 screws holding Hearth 3 Unplug White connector Block 4 Disconnect EARTH Wire from Control Valve Bracket 5 Unscrew 2nd EARTH Wire from Hearth 6 Loosen 4 screws holding Fan to the Back Panel keyhole slots 7 Remove Fan Back Panel Fan Screws Hearth ...

Page 15: ...eplace Pilot Set or re drill the injector Nozzle diameter LPG 0 35 mm NG 0 55 mm Replace POSSIBLE CAUSE AC Power IS unplugged or loose or the fuse has a short Battery power is too low when using DC power Battery Box has a failure or the connector pins are loose IR Receiver Fig 4 is covered POWER button of Remote Control Unit was not pressed for long enough Remote Control Unit has failed or there i...

Page 16: ...he terminals have loosened Valve M has a failure or Nozzle of Valve M is blocked Front Control Board has a failure Remote Control Unit has a failure The wire set has a failure or the terminals have loosened Valve L has a failure or Nozzle of Valve L is blocked Front Control Board has failed Remote Control Unit has failed Front Control Board has a failure Timer control incorrectly set e g am or pm ...

Page 17: ...position rocker switch 6624G Fan assembly QLZ06 1200 complete 6611G Otago Bay Log Set assembly 6611C Cross Logs Set of two left right twigs 1608FZ Door rope gasket 1610BX Glass 1611BX Glass thermotape seal 8315Fz Top panel Gunmetal 8115Fz Louvre 88 JL Left side panel State Colour 88 FzR Right side panel State Colour 89 Fz Main door State Colour 8900JJ2 Inner Door Panel frame 91 Fz Hearth Panel Sta...

Page 18: ...r any other indirect incidental cause are not covered by this warranty This warranty is void if the recommended service schedule is not implemented and carried out by a suitably qualified person as suggested in this manual Limitations of Liabilities Yunca Heating hereby waivers any liability for incidental and consequential damage directly or indirectly sustained or for any loss caused by the appl...

Page 19: ...Telephone Where Purchased Installed By Date Designed and Manufactured by Yunca Gas Dunedin PO Box 500 DUNEDIN 9054 Telephone 03 488 4342 Email dunedin yunca co nz Cut along here This section must be returned within 10 days of purchase YUNCA FUZiON WARRANTY REGISTRATION Serial No Gas Type Purchase Date Purchasers Name Purchasers Address City Postcode Telephone Where Purchased Installed By Date Retu...

Reviews: