background image

Page 8 of 9 

PIAZZA PATIO HEATER 

29/10/10 

Warranty:

 

The  Yunca 

PIAZZA 

All  Seasons  Patio  Heater  is  covered  by  a  limited  two-Year  Warranty 

against defects in materials and workmanship. 
All gas components, including control, burner, pilot assembly, tubing, regulator and hose, are 
warranted for a period of one year from date of purchase. 
Damage caused by neglect, improper use, acts of God, theft, or any other indirect, incidental 
cause are not covered by this warranty. 
This warranty is void if the recommended service schedule is not implemented and carried out  
by a suitably qualified person (refer servicing, page 6). 

 

Limitation of Liabilities 

Yunca Heating hereby waivers any liability for incidental and consequential damage directly or 
indirectly sustained, or for any loss caused by the application of this product not in accordance 
with the current printed instructions. 
Our liability is expressly limited to replacement of defective goods as per above warranty. Any 
claim shall be deemed waived unless made in writing to us within 30 days from the date that it 
was or reasonably should have been discovered.

 

 

Injector Sizes: 

 
GAS TYPE 

 
MAIN JET 

 
PILOT JET 

 
NATURAL 

 
2.80mm diameter 

 
0.35mm diameter 

 
L.P.G.  

 
1.60mm diameter 

 
0.23mm diameter 

  

PACKING PARTS PATIO HEATER

        

 

   

 

 

 

 

    

 

     TICK 

6524 

PATIO SPUN ALUMINIUM DOME (860MM DIA) 

 

0007D 

M6 STAINLESS WING NUT (X 3) 

 

 

MAIN GAS BODY 

 

6530PST 

BASE 

 

6545PST 

BASE PLATE 

 

6532C 

REMOVABLE  LEG 

 

6531C 

LEG (X 3) 

 

6536PST 

LEG CLAMP BRACKET (X 3) 

 

6535PST 

LEG PLATE & COLUMN PLATE ASSM 

 

0035 

M8 X 16 SET SCREW FRAME BOLT (X 6) 

 

0004, 0022, 
0004D,0032 

M8 X 110 BOLT, WASHER, NUT & WING NUT 
ASSY 

 

0022   

M8 SPRING WASHERS (X9) 

 

0004 

M8 NUTS (X 9) 

 

0036C 

M6X26MM ALLOY FLAT WASHER DOME x6 

 

0007D 

M6 STAINLESS HEX NUTS (X 3) 

 

 

REGULATOR 

 

 

NATURAL GAS KIT 

 

 
 
DATE: 

SIGNED:___   

 

____________ 

 

Summary of Contents for PIAZZA

Page 1: ...Page 1 of 9 PIAZZA PATIO HEATER 29 10 10 PIAZZA All SEASONS PATIO HEATER AUGUST 2010 OPERATIONS MAINTENANCE WARRANTY INFORMATION PLEASE RETAIN THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE ...

Page 2: ...tay with the appliance and is for the reference of the user and service person Only authorised service technicians should undertake any repairs or maintenance on this product It is recommended that the Heater has an annual maintenance check to ensure correct long term operation WARNING Do not store or use aerosols or other flammable materials near this appliance WARNING The Yunca All Seasons Patio...

Page 3: ...N TO POLE 4 POSITION COLUMN PIPE TO SOCKET 5 ALIGN HOLES SO THAT THE BOLT CAN PASS THROUGH 6 SECURE POLE INTO POSITION USING LOCK NUT 7 FASTEN BOTTLE SUPPORT LEG USING WINGNUT 8 BOLT DOME ONTO TOP SECTION Bracket Base Plate Leg and Column Support Gas Pipe Lock nut Bottle Support Leg Wing Nut Column Washer Hose Connection Wing Nuts 3 ...

Page 4: ...n full The heater will effectively heat a radius of around 3m so its position should be chosen to allow efficient use of heat without impeding peoples movement WARNING The clearances shown below are to be maintained at all times extra care should be taken when heater is used under tarpaulins or in marquees The base of the heater is filled with sand before assembly This improves stability of the Pa...

Page 5: ...hen running on Natural Gas the heater can be left mobile and connected to an approved bayonet fitting or may be permanently mounted and piped If the heater is being installed permanently connected to the supply a manual isolating valve should be installed as close as is practical to the appliance To get the maximum life from this product we suggest that it is covered when stored The Piazza All Sea...

Page 6: ...ure 7 Release the control knob slowly and turn to the flame setting required Changing a bottle LPG When the flame turns abnormally yellow and becomes smaller it is time to change the gas bottle To do this simply slide the round cylinder cover up the main stem to expose the gas cylinder Shut off gas supply at the gas bottle Remove the leg that is held on with a wing nut Disconnect regulator from th...

Page 7: ...omponents the perforated sheet metal cylinder that surrounds the control must be removed This is done by removing the screws top and bottom and the channel section pilot pipe cover As with all gas appliances regular servicing will improve the trouble free operation of this appliance This service should cover the following Leak test all joints Check operating pressures Clean main and pilot orifices...

Page 8: ...by the application of this product not in accordance with the current printed instructions Our liability is expressly limited to replacement of defective goods as per above warranty Any claim shall be deemed waived unless made in writing to us within 30 days from the date that it was or reasonably should have been discovered Injector Sizes GAS TYPE MAIN JET PILOT JET NATURAL 2 80mm diameter 0 35mm...

Page 9: ...nstalled By If permanent installation Date Manufactured in Dunedin by Yunca Gas PO Box 500 Dunedin 9054 Ph 03 488 4342 Email dunedin yunca co nz Cut along this line This section must be returned within 10 days of purchase Serial No Gas type Purchase Date Purchasers Name Purchasers Address City PostCode Telephone 0 Where Purchased Installed By If permanent installation Date Return to Yunca Heating ...

Reviews: