background image

Yunca_NZW_Operation_TOMMI - 2021-05-25.docx                                                                                                                 Page 7 of 7 

 

WARRANTY 

 

This  Yunca  Woodburner  is  warranted, 

with proof of purchase, to the first owner 
of  each  appliance  for  a  period  of  12 
months, commencing on date of delivery 
of the appliance in new and unused state.  
  

Repair  or  replacement  is  at  Yunca’s 

discretion and includes associated labour 
costs  but  excludes  freight  and  travel 
costs.  
  

This  warranty  does  not  cover  damage 

caused by mishandling, misuse, failure to 
follow the manufacturer’s installation and 
operating  instructions,  or  work  done  by 
others,  such  as  installers,  or  plumbers 
etc.  
  

The 

manufacturer 

shall 

not 

be 

responsible  for  site  conditions  such  as 
insufficient  draught,  downdraughts,  or 
routine servicing and adjustments.  
  

The following YUNCA heater components 

are replaceable parts and will be repaired 
(or replaced, if required) free of charge as 
a  result  of  defective  material  or 
workmanship  during  the  above  warranty 
period (12 months):  

-

 

Door seal and glass seal  

-

 

Combustion plate  

-

 

Refractory bricks and retainers  

-

 

Secondary air tubes  

-

 

Yunca Water boosters  

-

 

Yunca Flue systems  

-

 

Door handles and shafts  

-

 

Panels and castings  

-

 

Fan  

  

If a defect occurs, inform your dealer and 

the part will be repaired or replaced at our 
option.  
  

EXTENDED FIREBOX WARRANTY 

 

 

Your  Yunca  woodburner  firebox  is 
then  covered  by  an  extended  9-year 
warranty 

against 

defects 

during 

normal domestic use.  

 

  

During  the  extended  warranty  period 

Yunca  will  repair  or  replace,  free  of 
charge,  any  part  of  the  firebox  requiring 
repair  or  replacement  as  a  result  of 
defective  material  or  workmanship  in 
manufacture and/or assembly.   

In the case of a claim after the first  

12  months,  it  shall  be  the  owner’s 
responsibility and expense to deliver 

the Yunca fire to the dealer from whom it 

was 

purchased 

(should 

this 

be 

necessary),  and  the  reinstallation  after 
any repair has been made.  
  

Any  part  of  the  appliance  repaired  or 

replaced  free  of  charge  under  the 
warranty will continue to have the benefit 
of such warranty during the balance of the 
warranty period.  
  

The  warranty  does  not  extend  to 

consequential  loss  or  damage  to  either 
person(s) or property.  
  

The warranty is NOT available if

  

 

  

Repair  and/or  replacement  of  parts 
assemblies  which  are  necessary 
due  to  normal  wear  and  tear,  such 
as:  

1.1 

Cladding 

and 

body 

components:  door  and  panels 
enamelling 

and 

paintwork, 

brightwork  or  finishing  repairs 
due  to  causes  beyond  the 
control of the manufacturer or its 
franchised dealers  

1.2 

Flues: 

Cleaning 

of 

flues, 

removing 

creosote 

build-up 

from  flues,  weather  cap  and 
cowl.  

The  appliance  has  been  abused  in 
any  way  or  damaged  by  neglect, 
accident, improper use and has not 
been  operated  and  maintained  in 
accordance with the manufacturer’s 
recommendations.  

Damage resulting from acts of God 
and  natural  phenomena  such  as 
earthquakes, 

floods, 

landslips, 

sound vibrations and other damage 
caused 

by 

extreme 

weather 

conditions.  

Damage resulting from theft or other 
criminal acts.  

The  appliance  has  been  used  for 
commercial use or for purposes not 
specific  to  the  private  use  of  the 
purchaser.  

The  appliance  has  been  altered  by 
changing 

the 

manufacture

r’s 

specifications,  the  installation  and 
use  of  parts  and  assemblies  not 
genuine,  non-approved  for  use  by 
the manufacturer and  
the  removal  or  change  of  the 

manufacturer’s 

identification 

number or marks.  

Fuel  and  accelerants  are  used 
which are not recommended by the 
manufacturer.  

Any 

repair 

and/or 

adjustment 

performed  by  a  non-authorised 
dealer  or  installer,  or  damage 
resulting  there  from.  NOTE:  If 
unable  to  contact  Yunca  -  in  the 
case  of  an  emergency  the  selling 
dealer  can  submit  a  claim  for  the 
work involved and the manufacturer 
on its merits will consider it.  

 

The appliance and flue system may not be 

modified  in  any  way  without  written 
approval from Yunca Heating.  
  

WARNING: 

Any  modification  of  the 

appliance that has not been approved in 
writing  by  the  testing  authority  is 
considered as breaching AS/NZS 4013.  
  

Warranty Registration: 

(Please complete the following 

information for your records)  
  

MODEL: 

 

TOMMI

 

 

  

Serial Number_________________  

    

Purchase Date ________________   

  

Where Purchased______________   

 
____________________________ 
 
____________________________ 
 
____________________________  

  

Manufactured by  

 

Terry Young Ltd T/A Yunca Heating  
41 Onslow Street, Invercargill 9812  
PO Box 932, Invercargill 9840 
New Zealand  
 
Phone:     +64 3 216 6626  

Fax:         +64 3 216 2626  

Email:      

sales@yunca.co.nz

  

Web:        

www.yunca.co.nz

  

 
 

Summary of Contents for TOMMI

Page 1: ...ll members of your home understand how this remarkable heater works THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN ACCORDANCE WITH THESE INSTRUCTIONS Please fill out and return the r...

Page 2: ...RE REQUIRED BY THE REGULATORY AUTHORITY I E THE APPLIANCE SHALL BE IDENTIFIABLE BY A COMPLIANCE PLATE WITH THE MARKING TESTED TO AS NZS 4013 C ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPRO...

Page 3: ...TS TO START THE FIRE 6 Ensure both left and right control knobs are pulled out 7 Light all of the fire starter cubes using a long match or long reach gas lighter 8 Raise the door up with the handles i...

Page 4: ...trong draft 5 Close and latch the door shut once the fresh fuel load is fully engaged with flames 6 Close the right hand control knob once you are certain the fire will continue to build and there is...

Page 5: ...level of salt in their make up b Chemically treated timbers should also be avoided At best they generally don t burn as well as untreated timber At worst some of the chemicals may be noxious and pose...

Page 6: ...ck door glass seals replace where necessary Fan not Running No Power to Unit Ensure power is supplied to the unit and or have a registered Electrician inspect Water booster not performing Liming up of...

Page 7: ...ty The warranty is NOT available if 1 Repair and or replacement of parts assemblies which are necessary due to normal wear and tear such as 1 1 Cladding and body components door and panels enamelling...

Reviews: