operation  of  the  appliances  shall  be  provided  to  the  user.  The 
following content describes the relevant technical description of EMC. 
(Refer to Y0505-2012 for details)
The  basic  performance  of  this  product  described  in  the  scope  of 
application  will  not  be  affected  by  the  electromagnetic  environment 
stipulated in the EMC technical data.
■ Definition of EMC (electromagnetic compatibility)
EMC (electromagnetic compatibility) refers to the capability to satisfy 
the following two requirements.
1. It shall not send electromagnetic interference sounds outside the 
permitted range to other nearby electronic equipment. (Radiation)
2. The equipment can play its normal function in the electromagnetic 
environment where other electronic equipment sends out noise.
(Immunity)
■ Technical description related to EMC 
(electromagnetic compatibility)
Medical  electrical  equipment  shall  be  provided  with  special 
instructions about EMC and shall be used in accordance with the EMC 
information described below.
1.  This  product  requires  special  instructions  related  to 
electromagnetic  compatibility  (EMC).  Please  use  this  product 
according to the EMC information described in this manual.
2. Portable and radio frequency (RF) communication equipment may 
affect this product.
3. Do not use this product adjacent to or stacked with other equipment. 
(Except for communication)
4. Do not use products other than special accessories, otherwise ithey 
may increase the radiation and decrease the immunity.

Warning: 

apart  from  the  cables  sold  by  the  equipment  or  system 

manufacturer  as  spare  parts  of  internal  parts  and  components,  the 
use of other accessories and cables may increase the equipment or 
system's emission or decrease the immunity.

Table 1 Guidance and manufacturer statement - electromagnetic 
emission

This electric wheelchair is intended to be used in the electromagnetic 
environment  specified  below  and  the  purchaser  or  the  user  shall 
ensure this intended purpose.

Emission test

Compliance

RF emission 

GB4824

Group 1

RF emission

GB4824

Harmonic emission

GB17625.1

Voltage 

fluctuation, 

flicker emission 

GB17625.2

NA

NA

Electromagnetic

environment - guidelines

This electric wheelchair shall only 

use RF energy for its internal 

functions. Therefore, its RF 

emission is low and the possibility 

of interfering with nearby 

electronic devices is minimal

This electric wheelchair is suitable 

for use in the home and all 

facilities that are directly 

connected to the residential 
low-voltage supply network

(Corresponding to Table 201 in YY0505-2012)

Table 2 Guidance and manufacturer statement - electromagnetic
immunity

This electric wheelchair is intended to be used in the electromagnetic 
environment  specified  below  and  the  purchaser  or  the  user  shall 
ensure this intended purpose.

Immunity test

IEC60601

Test level

Coincidence

level

Electromagnetic

environment - guidelines

Class B

24

25

Summary of Contents for Electric-TIM I

Page 1: ...ion Address Yunyang Industrial Park Danyang Tel 0511 86900833 Fax 0511 86900878 Revision Date October 2017 530800 1A Electric Wheelchair Product Operation and Technical Instructions Please carefully r...

Page 2: ...nsure that the wheelchair is in good condition For any questions please contact the dealer or manufacturer and we will serve you wholeheartedly Do not operate your electric wheelchair before reading a...

Page 3: ...to avoid moisture Before powering on the controller confirm that the Manual Electric clutch of the left and right motors or the handle is in the Electric gear Do not switch the Manual Electric clutch...

Page 4: ...ry DC 24Vx18Ah lead acid battery DC 24Vx21Ah 11 Obstacle clearance height 40mm 12 Groove clearance width 100mm 13 Gradeability 6 14 Hill holding performance 9 15 Static stability 9 16 Dynamic stabilit...

Page 5: ...terclockwise direction after confirming that the eject pin has left the eject pin hole see Figure 8 To avoid pinching do not hold the seat tubes with your hands when pressing down the seat cushion Fig...

Page 6: ...igure 14 Figure 15 Figure 10 Use of movable leg when the electric wheelchair is provided with a movable leg turn the movable leg from the position in Figure 11 to the position in Figure 12 along the r...

Page 7: ...The gear increases by 1 each time you press this button and won t change after it reaches 5th gear Deceleration button Press this button to decrease the speed setting The gear decreases by 1 each tim...

Page 8: ...irection and the electric wheelchair will start moving increase the pushing range of the joystick to accelerate decrease the range to decelerate If it is necessary to stop the moving electric wheelcha...

Page 9: ...turer or purchase a battery of the same specification locally Tire pressure it is rec ommended to inflate the tires of 200 X 45 110 and 310 X 50 203 to 260 kpa maximum 325 kpa and inflate the tires of...

Page 10: ...s life 2 The battery is marked with obvious positive and negative electrode signs and a reliable connector is provided to ensure the normal 16 17 connection of the circuit Non specialized persons sho...

Page 11: ...in unchanged c Pay attention to distinguish between the positive and negative electrodes on both sides of the wiring harness For the right hand battery connecting wires connect the red wire with the p...

Page 12: ...is eliminated press the button to reset manually see Figure 23 Note only the lead acid battery is provided with an overload protector If a lithium battery is used it will cut off the power during ove...

Page 13: ...is not connected reliably Please connect it again 4 The motor does not work 10 Electromagnetic Compatibility This product complies with the requirements of the related content in the EMC electromagnet...

Page 14: ...mmunication 4 Do not use products other than special accessories otherwise ithey may increase the radiation and decrease the immunity Warning apart from the cables sold by the equipment or system manu...

Page 15: ...ment guidelines RF conduction GB T17626 6 GB T18029 21 RF radio frequency radiation charger GB T17626 3 GB T18029 21 RF radio frequency radiation wheelchair GB T17626 3 GB T18029 21 3V m 150kHz 80MHz...

Page 16: ...e 204 in YY0505 2012 This electric wheelchair is intended to be used in an electromagnetic environment with controlled radioactive radiation The purchaser or user of the electric wheelchair can preven...

Page 17: ...l and human factors Faults caused by failing to comply with the correct operation methods in these instructions Damage caused by unpredictable natural No 1 2 3 Parts Frame Controller Motor Warranty pe...

Page 18: ...7 Model Total length mm Total width mm Total height mm Seat width mm Seat height mm Seat depth mm Handrail height mm Handrail spacing mm Seatrest height mm Ground clearance of foot support mm Front wh...

Reviews: