background image

4

DynaPak 2010 Gas Sampler
The DynaPak 2010 Sampler is a pipeline mounted
system which uses the pneumatically operated,
positive displacement DynaPak 2000 pump, the
Z-65 timer/controller, the YZ filter/regulator and a
low power solenoid valve to obtain gas samples.
The 2010 provides three modes of operation:

A. Time-based sampling:  in this mode of
operation, the 2010 extracts a gas sample from
the pipeline at regular time intervals.  The volume
of the sample is set by the operator using the
volume adjustment feature of the DP-2000 pump.
The Z-65 controller operates as a recycling timer,
periodically energizing a low power solenoid valve.
Energizing the solenoid valve allows actuation gas
to stroke the DP-2000 pump.  The rate at which
this occurs is a function of operator input.  Two 10
position switches are used to set the off time
interval.  The number of times the solenoid output
is activated is recorded by the onboard LCD stroke
indicator.

B. Time-based sampling  with the Optional
YZ differential pressure switch (DPS-2): 
 this
mode of operation is similar to the time-based
sampling mode, except that the DPS-2 converts a
differential pressure signal to an electrical signal
that the Z-65 timer uses to determine if flow is
present in the pipeline.  In effect, the DPS allows
the Z-65 timer to shut off when flow stops in the
pipeline, and when flow starts again, the ability to
start-up and resume operation.

C. Proportional-to-flow sampling:
in this mode of operation, the Z-65 counter
operates as a dividing counter.  The Z-65 counter
periodically energizes a low power solenoid valve.
As in the other two modes of operation, this allows
actuation gas to stroke the DP-2000 pump.  The
rate at which this occurs is a function of operator
input as well as the host computer or other device
that inputs pulses per volume metered.  The two
10-position switches on the Z-65 are used to set
the number of pulses the counter will count before
activating the solenoid output.  The number of
times the solenoid output is activated is recorded
by the onboard LCD stroke indicator.  Sample
volume is again controlled using the DP-2000
volume adjustment knob.

In all three modes of operation, the Z-65 timer/
counter operates using a replaceable internal
battery pack.  The battery pack condition is
monitored by way of two indicator LEDs.  When
the battery pack needs replacement, the red LED
will illuminate when the solenoid output is
activated.  If the battery pack is good, the green
LED will illuminate when the solenoid is activated.

The External Power Option can be used in lieu
of the internal battery pack.  The External Power
Option (model # EPO-120) consists of an AC to
DC convertor and intrinsically safe barrier to
convert 120 VAC power to 28 VDC to operate the
controller without the use of the internal battery
pack.

The Solar Power Option would be used in lieu of
the internal battery pack.  The Solar Power
Option 
(model #SPO-12) consists of a 5 watt
solar panel with RM-12 charger regulator module
and internal 12V, 5 Amp hour battery pack.

3. Theory of Operation

Summary of Contents for DynaPak 2010FKNX

Page 1: ...DynaPak2010FKNX SystemSupport Manual Version 09242003...

Page 2: ...sampling with the DPS 2 12 10 Sampler Set Up proportional to flow sampling 14 11 Sampler Maintenance 16 12 Trouble Shooting 20 13 Diagrams 1 DP 2000 pump assembled 24 2 DP 2000 pump exploded 25 3 YZ...

Page 3: ...ns concerning installation operation contact your YZ representative or YZ Customer Service at 936 788 5593 2 System Components The primary components of the DynaPak 2010 Sampling System are illustrate...

Page 4: ...l to flow sampling in this mode of operation the Z 65 counter operates as a dividing counter The Z 65 counter periodically energizes a low power solenoid valve As in the other two modes of operation t...

Page 5: ...uld cause aerosols or significant pressure drops 4 2 The sampler should not be located within the defined meter tube region AGA 3 manual A The number of unobstructed straight pipe diameters upstream s...

Page 6: ...as supply connection for the Filter Regulator located on the left side of the sampler enclosure CAUTION Incorrect operation of valves over tightening can result in damage to the valve components isola...

Page 7: ...pressure supply valve without ensuring that the equalization valve is open Failure to do so may damage the DPS 2 s internal components d Open the other supply valve e Close the equalization valve f Ru...

Page 8: ...lume constant pressure cylinder The free floating piston cylinder DuraSite may be installed in a horizontal position on an optional vessel rack Free floating piston cylinders should NOT be installed o...

Page 9: ...stroke 7 4 Move all of the mode switches on the Z 65 to their off positions 7 5 Move both timer counter dials to the 0 position 00 minutes 7 6 Move mode switches 1 2 and 3 to the on position The pump...

Page 10: ...E The time 18 minutes above corresponds to the dial setting shown for the Z65 model with the timer range setting in the factory position jumper on the two left pins See section 12 4 Timer Range Settin...

Page 11: ...8 6 Turn mode switch 3 to on 8 7 Turn mode switch 4 to off 8 8 Press the test button once to initiate the timer sequence 8 3 Adjust the pump volume adjustment knob to the value used in the calculatio...

Page 12: ...18 minutes above corresponds to the dial setting shown for the Z65 model with the timer range setting in the factory position jumper on the two left pins See section 12 4 Timer Range Setting 3 2 0 9...

Page 13: ...6 Turn mode switch 3 to off 9 7 Turn mode switch 4 to off 9 8 Press the test button once to initiate the timer sequence NOTE For the Z 65 to operate the DP 2010 System a minimum pressure differential...

Page 14: ...incoming connections to the Z 65 terminal strip see illustration b Turn mode switch 1 to on c Turn mode switch 2 to off d Turn mode switch 3 to on e Turn mode switch 4 to off OR 10 3 If the input is...

Page 15: ...er of pulses you want to count before the sample pump strokes Example 20 pulses turn dials to 20 Press the test button once to load the value into the memory NOTE If the calculated counter setting is...

Page 16: ...ample discharge 1 8 stainless steel tubing from the pump body d Screw the stroke adjustment knob all the way down to the 0 cc stroke setting e Unscrew the pump body by hand from the inlet check valve...

Page 17: ...rings and bushings to prevent damage j Install the body bushing into the bottom of the pump body NOTE Apply a light coat of assembly grease on the plunger shaft prior to installation k Insert all oth...

Page 18: ...te if the battery is low NOTE The solenoid must be connected to test the battery condition Battery condition cannot be tested with a volt meter Replacing a Depleted Battery 1 Remove the four thumb scr...

Page 19: ...the DynaPak 2000 Series gas samplers Part Number Description Qty Location C4 0004 Filter element 1 see diagrams 3 and 4 D3 0002K DP 2000 pump seal kit 1 see diagrams 1 and 2 D3 0003 YZ filter regulat...

Page 20: ...the DPS is sensing flow in the pipeline the green LED should illuminate If flow is not present the red LED should illuminate 12 3 LCD Stroke Indicator Test Mode A To test the stroke counter set the m...

Page 21: ...he factory position far left position 12 4 Timer Range Setting A There are two Z 65 models the Z 65 6 1 and Z 65 6 03 Each Z 65 timer has two ranges for the timer setting dials 1 Z 65 6 1 Range Settin...

Page 22: ...g b xx minutes set the configuration jumper to the center position Note To obtain maximum battery life choose the longest solenoid stroke rate possible WVWCN 5 UVGO 4463 CEVQT factory positioned for 1...

Page 23: ...green LED will turn on and off and the red LED will illuminate again This will normally occur very quickly and give the appearance that the green LED blinks on when the pulse input is received and re...

Page 24: ...eck Valve Spring Guide Inlet Check Valve Spring O Ring 006 P N A5 1006 O Ring 012 P N A5 1108 O Ring 108 P N B1 0014 Male Connector 1 8 P X 1 8 T P N B1 0015 Pump Body P N B1 0011 Spring Retainer Plun...

Page 25: ...30 Set Screw P N C0 0096 P N C0 0014 Cap Screw 6 Each O Ring 012 P N B1 0020 P N C0 0026 Inlet Screen P N C4 0006 P N C3 0008 P N C4 0022 20 Micron Filter Inlet Check Valve Spring Inlet Check Valve Sp...

Page 26: ...26 Diagram 3 YZ filter regulator assembled...

Page 27: ...0073 O Ring 012 Retaining Nut P N A5 1012 Seat P N A3 0072 Upper Dart P N A3 0071 Upper Spring P N C3 0010 P N A3 0070 Piston P N A3 0069 Piston Spring Spring Cap P N A3 0068 P N A3 0067 Bonnet Pneuma...

Page 28: ...Steel Set Screw Inlet Rupture Disc 1800 psi P N A3 0083 Rupture Disc Retainer P N A3 0084 YZ Valve Body P N A3 0137 0 1000 PSI LinkPlus Model No C1 0005 0 2000 PSI LinkPlus Model No C1 0006 0 600 PSI...

Page 29: ...005 Set Screw P N E0 5001 Magnet Diaphragm SS Hex Nut P N C0 0048 Qty 8 P N A6 0013 P N G2 0002 Cable Assembly 30 Ft Shrink Wrap SS Bolt P N C0 0047 Qty 8 P N H2 0002 Qty 2 Magnet Support Body Diaphra...

Page 30: ...65 6 Controller Assembly 1 1 Model Z 65 6 1 F2 0001 Model Z 65 6 03 F2 0018 2 Battery Pack E3 2001 1 3 Stroke Counter Assembly G1 0001 1 4 Terminal Strip 6 Position H1 0001 1 5 BCD Switch E1 0001 2 6...

Page 31: ...ersion 09242003 YZ Systems Inc 3101 Pollok Drive Conroe Texas USA 77303 P 936 788 5593 F 936 788 5720 31 Diagram 8 Z 65 Installation Notes Wiring Control Documentation System Installation Notes and Re...

Page 32: ...the pre charge gas too fast 2d When the cylinder becomes a maximum of 80 full see volume indicator all valves should be closed The product connection is slowly broken in order to vent any trapped pro...

Page 33: ...YZ UniValve Purge Valve Nut P N A3 0080 P N A3 0063 Valve Seat P N C6 1003 Ser 4608 P N 12 1006 Ser 0321 and Prior P N 12 1007 Ser 0322 0613 P N 12 1008 Ser 0614 4087 P N C6 1002 Ser 4088 Piston Wash...

Page 34: ...34 Notes...

Page 35: ...DP 2010FKNX Version 09242003 YZ Systems Inc 3101 Pollok Drive Conroe Texas USA 77303 P 936 788 5593 F 936 788 5720 35 Notes...

Page 36: ...ility and fitness for a particular purpose with respect to the product This limited warranty gives you specific legal rights You may have others which vary from state to state These remedies are not a...

Reviews: