YZ Systems, Inc. • 3101 Pollok Drive • Conroe, Texas • USA • 77303 • P: 936.788.5593 • F: 936.788.5720
Page 46
DP-2010FU ver.04202004
SSSSS
ECTION
ECTION
ECTION
ECTION
ECTION
11:
11:
11:
11:
11: S
S
S
S
S
Y
YY
Y
YSTEM
STEM
STEM
STEM
STEM
TTTTT
R
RR
R
ROUBLESHOO
OUBLESHOO
OUBLESHOO
OUBLESHOO
OUBLESHOOTING
TING
TING
TING
TING
3. Unscrew the thumbscrews and
remove the six position terminal strip
and cover. This will expose the battery
pack and the three position configura-
tion jumper (located in the lower right
corner of the Z-65 controller assem-
bly).
4. Set the configuration jumper to the far
right position marked stroke indicator
test, figure 44.
5. This will cause all six digits to become
active on the stroke counter. Depress
the reset. The stroke counter should
increment 000000, 111111, etc., up to
999999 each time the solenoid fires.
When the counter display reads
999999, the test is complete.
Timer Range Setting
There are two Z-65 models:
the Z-65/6.1 and Z-65/6.03. Each
Z-65 timer has two ranges for the
timer setting dials.
1. Z-65/6.1 Range Setting:
xx minutes: set the configura-
tion jumper to the far left posi-
tion (factory setting), figure 45.
x.x minutes: set the configura-
tion jumper to the center posi-
tion, figure 46.
12.3 d - Jumper switch location
Approved
Factory
System
figure 44
factory positioned
for 1 - 99 counts (xx)
Jumper switch location
Jumper switch location
for .1 - 9.9 counts (x.x)
Mutual
System
Approved
Factory
Mutual
System
Approved
Factory
IMPOR
IMPOR
IMPOR
IMPOR
IMPORTTTTTANT NO
ANT NO
ANT NO
ANT NO
ANT NOTE:
TE:
TE:
TE:
TE:
When the test is complete, move the jumper back
to the factory position (far left position).
IMPOR
IMPOR
IMPOR
IMPOR
IMPORTTTTTANT NO
ANT NO
ANT NO
ANT NO
ANT NOTE:
TE:
TE:
TE:
TE:
To obtain maximum battery life, choose the longest
solenoid stroke rate possible.
figure 45
figure 46