YZ Systems, Inc. 3101 Pollok Drive Conroe, Texas USA 77303 P: 936.788.5593 F: 936.788.5720
Page 42
DP-2010 TP ver.10012004
S
ECTION
11: S
YSTEM
T
ROUBLESHOOTING
BatteryPower
The Z-65 controller, and the low powered solenoid are
normally powered by the Z-65 Battery Assembly. The
battery assembly is not a rechjargable type battery.
Under normal sampling conditions this battery may last
2 years. A built in warning LED is provided to advise the
operator when the Battery needs changing.
Battery Power
Troubleshooting Steps
1. Set the mode
swi
tches as follows, figure 28:
Position 1, 2 and 3 on
2. Set the
time switches
to the 01 position,
figure 29. This will set the solenoid output rate
to one actuation every one minute (based on
the factory set time range for the Z-65 model,
3. Depress the
test switch
to test the battery. A
green LED will illuminate if the battery is good
and a red LED will illuminate if the battery is
low, figure 30.
figure 28
figure 29
IMPORTANT NOTE:
Time switches must
not
be in 00 position to test
the battery.
IMPORTANT NOTE:
The solenoid must be connected to test the
battery condition.
Battery condition cannot be
tested with a volt meter.
figure 30