YZ Systems, Inc. 3101 Pollok Drive Conroe, Texas USA 77303 P: 936.788.5593 F: 936.788.5720
Page 46
DP-2010 TP ver.10012004
S
ECTION
11: S
YSTEM
T
ROUBLESHOOTING
3.
Unscrew
the thumbscrews and
remove
the six position terminal strip
and cover. This will expose the battery
pack and the three position configura-
tion jumper (located in the lower right
corner of the Z-65 controller assem-
bly).
4.
Set
the configuration jumper to the far
right position marked stroke indicator
test, figure 44.
5. This will cause all six digits to become
active on the stroke counter.
Depress
the reset. The stroke counter should
increment 000000, 111111, etc., up to
999999 each time the solenoid fires.
When the counter display reads
999999, the test is complete.
Timer Range Setting
There are two Z-65 models:
the Z-65/6.1 and Z-65/6.03. Each
Z-65 timer has two ranges for the
timer setting dials.
1. Z-65/6.1 Range Setting:
xx minutes:
set
the configura-
tion jumper to the far left posi-
tion (factory setting), figure 45.
x.x minutes:
set
the configura-
tion jumper to the center posi-
tion, figure 46.
G-XPSHUVZLWFKORFDWLRQ
/WVWCN
#RRTQXGF
(CEVQT[
5[UVGO
figure 44
IDFWRU\SRVLWLRQHG
IRUFRXQWV[[
-XPSHUVZLWFKORFDWLRQ
-XPSHUVZLWFKORFDWLRQ
IRUFRXQWV[[
/WVWCN
5[UVGO
#RRTQXGF
(CEVQT[
/WVWCN
5[UVGO
#RRTQXGF
(CEVQT[
IMPORTANT NOTE:
When the test is complete, move the jumper back
to the factory position (far left position).
IMPORTANT NOTE:
To obtain maximum battery life, choose the longest
solenoid stroke rate possible.