YZ Systems Milton Roy • 201 Ivyland Road • Ivyland, Pennsylvania • USA • 18974 • P: 281.362.6500 • www.yzsystems.com
Page 11
NJEX EUR ver. 08-2021
Section 2: System Installation
Figure 9
Figure 10
Expansion
Tank
NJEX Gas
Filter
Bulk Odorant Filter
Actuation Gas Regulator
•
Bulk Odorant Filter,
figure 9,
provides primary
odorant filtration between the storage tank and the
NJEX. The bulk odorant filter is pre-installed inside
the system enclosure attachment to the odorant
source is via a bulk filter manifold equipped with
1/4” FNPT connection located on the back of the
system enclosure.
•
Mechanical Interconnect Cable
,
figure 9,
pro-
vides the connection between the system control
enclosure and the electrical components located in
the mechanical section.
•
Expansion Tank,
figure 10,
provides a closed
loop system for pressure fluctuations within the
Verometer during the odorant fill and injection
cycle.
•
NJEX Gas Filter
,
figure 10,
installed between
the actuation gas regulator and the actuation gas
manifolds provides a 25 micron coalescent filtration
to insure a clean pneumatic supply.
•
Actuation Gas Regulator,
figure 9,
provides addi-
tional regulation of supply gas to actuate the pump.
•
Service Tray,
(Not Illustrated),
should be installed
in the bottom of the system enclosure, to capture
any drops that may occur during servicing of the
odorizer.