Section 5: Programming for Proportional-to-Flow Operation
Or
Or
Setting Operator Input Parameters
• Choose
Set
in the main menu,
figure 27
.
• Choose
Par
–
parameters
in the set selection menu,
figure 28
.
• Choose
Flow
in the set parameters menu,
figure 29.
• Choose
Set
in the proportional-to-flow menu,
figure
30
.
Setting the odorant injection rate in mg/m3 of
gas
To set the injection rate,
figure 31
, press and release
the
Select
key. The value entry will begin to flash
when chosen. Use the
Up Arrow
key to increase the
value and the
Down Arrow
key to decrease the value.
When a new value has been chosen, press the
Enter
key to store the new value into memory. The entered
value will stop flashing when it has been loaded into
memory. Press the
Down Arrow
key to advance to
the next parameter.
Pump displacement in cc/stroke
To set the pump displacement,
figure 32,
press and
release the
Select
key. The value entry will begin to
flash when chosen. Use the
Up Arrow
key to in-
crease the value and the
Down Arrow
key to de-
crease the value. When a new value has been cho-
sen, press the
Enter
key to store the new value into
memory. The entered value will stop flashing when it
has been loaded into memory. Press the
Down Ar-
row
key to advance to the next parameter.
Odorant density in g/cc @ 15.5º C.
To set the
odorant density,
figure 33,
press and release the
Select
key. The value entry will begin to flash when
chosen. Use the
Up Arrow
key to increase the value
and the
Down Arrow
key to decrease the value.
When a new value has been chosen, press the
Enter
key to store the new value into memory. The entered
value will stop flashing when it has been loaded into
memory. Press the
Down Arrow
key to advance to
the next parameter.
pmp bat vmtr sig tnk
PropFlow
Idle
*Strt *Dsp *Set
*
designates optional key function
pmp bat vmtr sig tnk
Set Parameters
*Flow *Time *Esc
pmp bat vmtr sig tnk
Set Selection
*Par *Cal *Esc
Figure 27
pmp bat vmtr sig tnk
Proportional to Flow
*Set *Alarm *Esc
pmp bat vmtr sig tnk
Odorant Density
6.80 lbs/Gal
pmp bat vmtr sig tnk
Odorant Density
0.815 9/cc
pmp bat vmtr sig tnk
Injection Rate
1.00 lbs/MMCF
pmp bat vmtr sig tnk
Injection Rate
16.0 mg/m
3
Select
Enter
pmp bat vmtr sig tnk
Pump Displaceplent
1.000 cc/Stroke
Select
Enter
Select
Enter
Figure 28
Figure 29
Figure 30
Figure 31
Figure 32
Figure 33
pmp bat vmtr sig tnk
Set Parameters
*Flow *Time *Esc