Section 6: Programming for Proportional-to-Time Operation
Or
*designates optional key function
pmp bat vmtr sig tnk
Set Parameters
*Flow *Time *Esc
pmp bat vmtr sig tnk
Proportional to Time
*Set *Alarm *Esc
pmp bat vmtr sig tnk
Odorant Density
6.80 lbs/Gal
pmp bat vmtr sig tnk
Odorant Density
0.815 9/cc
pmp bat vmtr sig tnk
Set Selection
*Par *Cal *Esc
pmp bat vmtr sig tnk
PropFlow Idle
*Strt *Dsp *Set
pmp bat vmtr sig tnk
Pump Displacement
1.000 cc/Stroke
Select
Enter
Select
Enter
Select
Enter
Figure 57
Figure 58
Figure 59
Figure 60
Figure 61
Figure 62
Figure 63
Setting Operator Input Parameters
Choose
Set
from the main menu,
figure 57
.
Choose
Par
from the set selection menu,
figure 58
.
Choose
Time
from the set parameters menu,
figure 59
.
Choose
Set
from the proportional-to-time menu,
figure 60
.
Pump displacement in cc/stroke
To set the pump displacement,
figure 61
,
press and
release the
Select
key. The value entry will begin to
flash when chosen. Use the
Up Arrow
key to in-
crease the value and the
Down Arrow
key to de-
crease the value. When a new value has been cho-
sen, press the
Enter
key to store the new value into
memory. The entered value will stop flashing when it
has been loaded into memory. Press the
Down
Arrow
key to advance to the next parameter.
Odorant density in
g/cc
@ 15.5ºC
To set the odorant density
,
figure 62,
press and
release the
Select
key. The value entry will begin
to flash when selected. Use the
Up Arrow
key to
increase the value and the
Down Arrow
key to
decrease the value. When a new value has been cho-
sen, press the
Enter
key to store the new value into
memory. The entered value will stop flashing when it
has been loaded into memory. Press the
Down Arrow
key to advance to the next parameter.
Time interval between strokes of the pump in
xx.xx minutes/stroke:
1. 0.00 minutes = proportional-to-time disabled.
2. 0.02 to 99.99 minutes = proportional-to-time en-
abled.
To set the time/strokes
,
figure 63
,
press and release
the
Select
key. The value entry will begin to flash
when chosen. Use the
Up Arrow
key to increase the
value and the
Down Arrow
key to decrease the value.
pmp bat vmtr sig tnk
Set Time Per Stroke
0.50 minutes