YZ Systems Milton Roy • 201 Ivyland Road • Ivyland, Pennsylvania • USA • 18974 • P: 281.362.6500 • www.yzsystems.com
Page 69
NJEX EUR ver. 08-2021
Section 11: System Operation
Figure 188
pmp bat vmtr sig tnk
PropFlow Stop
*Start *Dsp *Set
Figure 188
pmp bat vmtr sig tnk
Meter Level 000%
Filling
pmp bat vmtr sig tnk
Proportional to?
*Flow *Time *Esc
pmp bat vmtr sig tnk
Start Pump?
*Yes *No *Esc
pmp bat vmtr sig tnk
Prop Flow/Time 0:00:00
*Stop *Dsp *Set
pmp bat vmtr sig tnk
Time/Stroke Calculated
Exceeds minimum
pmp bat vmtr sig tnk
Stop Pump?
*Yes *No *Esc
Figure 189
Figure 190
Figure 191
Figure 192
Figure 193
pump a minimum of 20 times. Additional strokes may
be necessary if the pump displacement is restricted
with a pump stroke spacer.
A decrease in the Verometer Level should be ob-
served. Close valve
V3
and press the
Up Arrow
key
four times to return to the main menu.
Choose the
*Start
entry from the main menu,
figures
188
. The meter level display will indicate the Verom-
eter level as the verometer refills to 100%.
Next, choose the mode of operation in the Proportional-
to-Flow or Time display, for either the
*Flow
or
*Time
entry,
figure 189.
Note:
the
*Time
option will not appear if disabled at
the time interval setting,
ming for Proportional-to-Time Operation, page 33,
Time Interval between strokes of the pump....
To start the pump press the
*Yes
entry,
figure 190
.
If the calculated time / stroke is less than the mini-
mum, the
Time / Stroke Calculated Exceeds Mini-
mum
display will appear, and the system will not
start,
figure 191
.
Refer to Section 5, page 27, Propor
tion-to-Flow Mode, Setting Operator Input Parameters,
to set the correct parameters for the NJEX System
The
Prop Flow / Time x:xx:xx
display that follows,
figure 192,
provides a count down to the next pump
stroke.
To Stop The System
To stop the pump, in the
Prop Flow/Time x:xx:xx
display,
figure 192,
press the
*Stop
entry. The follow-
ing
Stop Pump
display,
figure 193,
then provides the
option to press the
*No
or
*Yes
entry. Press the
*Yes
entry to stop the pump.