Section 2: System Installation
'A'
8-10 AWG
Grounding Rod
Depth of
4'-0" Min.
FRONT VIEW
SIDE VIEW
BACK VIEW
'B'
'C'
Standard System Mounting
Figure 5
1. Bolt down the system enclosure to a concrete
slab using the mounting holes (9/16" (14.29mm))
provided in the bottom of each leg of the enclosure.
Recommended bolt/stud sizes for mounting the
enclosure is 1/2" (12.7mm).
2. In order to satisfy NEC requirements you
must connect a ground wire from the ground-
ing lug located on the enclosure leg to a prop-
erly installed ground rod, located adjacent to
the system enclosure. *Resistance to ground
must be less than 1 Ohm. To assure proper
system operation this ground should not be a
shared ground with any other equipment.
TABLE
A
B
C
SINGLE
527.05 mm
514.35 mm
228.6 mm
DUAL
1022.35 mm
1003.3 mm
228.6 mm