Section 1: First Things To Know About The 7300G
Theory of Operation
Operation of the 7300G centers around three primary
components: the Model 7000 pump, the Model
VM-1100 Verometer and the Model N-300G controller.
During normal operation, the Model 7000 pump injects
an exact quantity of odorant at a rate determined
by the N-300G controller. The quantity of odorant
injected per stroke is set using a spacer in the pump
actuation assembly. The rate at which the pump is
actuated is determined by the N-300G controller.
The VM-1100 Verometer serves as a temperature
compensated meter which verifies the amount of
odorant injected by the Model 7000 pump. The N-
300G controller uses an input signal from the Verom-
eter to determine the amount of odorant that has
been injected, as well as the odorant level within the
Verometer. Once the odorant level falls to a predeter-
mined low level point, the N-300G controller actuates
a solenoid valve which opens the fill valve, allowing
the Verometer to be refilled. Once the Verometer is
filled, the N-300G controller closes the fill valve.
The N-300G controller allows the 7300G system to
operate in either a time-based mode or a proportional-
to-flow mode. In the time-based mode of operation,
the N-300G controller actuates the Model 7000 pump
at a regular time interval preset by the operator.
In the proportional-to-flow mode of operation, the
N-300G controller uses a customer provided gas flow
rate input signal and several operator input values
to calculate the time between strokes of the pump.
These operator input values include the odorant injec-
tion rate (lbs/MMCF or mg/m3), pump displacement
(cc/stroke), and the odorant density (lbs/gal or g/cc).
The flow input signal is customer provided by either a
flow computer or other flow monitoring devices. In this
mode, the controller has the capability to distinguish
between a low flow situation and a loss of flow input
signal. For systems with analog inputs, if a loss of
flow signal occurs, the controller automatically defaults
back to a pre-selected percentage of the flow input.
The flow input signal is read by the N-300G controller
eight times per pump stroke. These readings are aver-
aged and the time duration until the next stroke is then
calculated by the controller. The maximum time be-
tween strokes is 99.99 minutes (when gas is flowing),
regardless of the time calculated by the controller.
CAUTION:
Excessive tubing lengths should be avoided. Instal-
lation of the NJEX Odorization system should be as
close to the point of injection and Odorant Storage
Tank as possible. Maximum tubing length should not
exceed 15’ (4.5 meters) with the tubing size main-
tained as indicated in this manual. If longer tubing
lengths are required consult YZ Systems Technical
Services at; 800.653.9435 or 1.281.362.6500.
System Accessories
• Odorant Injection Probe, includes a 316 stainless
steel probe, and isolation valve for location at the
pipeline. When ordering, please specify pipeline
connection required, 1/2” or 3/4”.
• Odorant Injection Probe with Sightglass, includes
a 316 stainless steel probe, visual odorant sight
indicator, and an isolation valve for location at the
pipeline. When ordering, please specify pipeline
connection required, 1/2” or 3/4”.
• 1/4” stainless steel discharge tubing In-line Check
Valve. For placement in the odorant discharged
tubing line immediately preceding the probe assem-
bly, (P/N A3-0024).
• 1/4” stainless steel tubing Dielectric Isolator Union.
These should be installed in every tubing line that
attaches the odorizer to the pipeline in any manner.
For example the supply gas, odorant discharge, and
differential pressure switch connections, (P/N A1-
0182).
• NJEX Scrubbers. These filters are designed to
scrub the exhaust gas vented from the pumps or
Overflow Protector of the Expansion Tank. They are
available by ordering P/N C4-0018, 15 gallon scrub-
ber.
A complete line of odorization accessories ranging
from pre-odorized gas scrubbers to injection probes is
available through YZ. Please contact your local
representative or YZ toll free at 800.344.5399. For
technical support call 800.653.9435.