SECTION 5: SYSTEM CONTROL ELECTRONICS
YZ Systems Milton Roy • 201 Ivyland Road • Ivyland, PA • USA • 18974 • P: 281.362.6500 • www.yzsystems.com
Page 46
NJEX ZEO Version 04/13/2021
Calculation for Determining the Span Frequency
𝑃𝑢𝑙𝑠𝑒
𝐶𝐹
𝑥 max 𝑓𝑙𝑜𝑤 𝑟𝑎𝑡𝑒
𝐶𝐹
𝐻𝑟
=
𝑃𝑢𝑙𝑠𝑒𝑠
𝐻𝑟
As determined by the flow metering device
Example:
1 𝑝𝑢𝑙𝑠𝑒
10 𝐶𝐹
𝑥
1,000,000 𝐶𝐹
𝐻𝑟
= 100,000
𝑝𝑢𝑙𝑠𝑒𝑠
𝐻𝑟
Since pulses per hour is not an option for programing the N-400 controller, divide by 60
minutes per hour to obtain pulses per minute.
100,000 𝑝𝑢𝑙𝑠𝑒𝑠
𝐻𝑟
𝑥
1 𝐻𝑟
60 𝑚𝑖𝑛
= 1,666.7
𝑝𝑢𝑙𝑠𝑒𝑠
𝑚𝑖𝑛
Since a maximum of 999 pulses per minute may be programmed into the N-400 controller,
you must now divide by 60 seconds per minutes to obtain pulses per second. If this value
had calculated to be less than 100 pulses per minute, it could have been programmed into
the N-400 controller.
1,666.7 𝑝𝑢𝑙𝑠𝑒𝑠
𝑚𝑖𝑛
𝑥
1 𝑚𝑖𝑛
60 𝑠𝑒𝑐
= 27.7
𝑝𝑢𝑙𝑠𝑒𝑠
𝑠𝑒𝑐