YZ Connect Overview 

Selecting an NJEX or ZEO Odorizer 

After logging into YZ connect via 

www.yz-connect.com

 or the mobile app, there are two options (map or 

list) to select an odorizer.  Whatever is selected will be the default next time a user logs in. 

 

Map - select the unit and click the name to view the dashboard 

 

List - select the unit to view the dashboard 

 

If you are viewing an odorizer select the 

 icon to see the list of odorizers again 

 

Odorizer Management Overview 

Main, Reports and Setup are the three menu options on the top toolbar.  Select one to see drop down 

options.  From the mobile app select the 

 to access the menu options for an odorizer. 

 

 

 

Main – Contains all the critical information about the odorizer 

 

o

 

Snapshot/User Snapshot – Latest performance data on the unit.  Admin level or above 
can view and control units with commands available in this tab.  User level will see the 
User Snapshot and can only view the data and select “Get Status” to refresh it. 

o

 

Alarms – Shows all alarms that are currently active 

o

 

Alarm Log – Shows a log of all alarms, when they happened, and when they cleared 

Summary of Contents for YZ Connect

Page 1: ...User Manual V1 0...

Page 2: ......

Page 3: ...s 7 YZ Connect Overview 5 Selecting an NJEX or ZEO Odorizer 5 Odorizer Management Overview 5 Functionality Overview 8 N 300 NJEX Snapshot 8 N 400 ZEO Snapshot 9 Alarms 9 Alarm Log 10 Event Log 10 Chan...

Page 4: ...higher users can control the odorizer and change parameters remotely USER level accounts only have the ability to remotely monitor equipment and cannot control or make parameter changes YZConnectLogi...

Page 5: ...ns SAFE AREA ONLY not approved for installation in Hazardous locations Installation Indoor Outdoor Enclosure NEMA 4X IP67 Ambient 4 to 140 F 20 to 60 C Electrical Single Phase 115 230VAC 0 55A 0 35A 5...

Page 6: ...reception when necessary To mount the antenna drill a hole 10 11mm 0 4 0 43 in diam and mount using the provided nut washer and foam sticker to maintain the IP rating Route the two antenna cables thro...

Page 7: ...y Voltage Single Phase 115 230VAC 50 60Hz Current 0 55A 0 35A 115 230V Required Wire Size 16AWG 1mm2 Wire Terminal Torque 4 4 lb in 5 kgf cm Wiring Overview Max RS 485 cable length between N 300 or N...

Page 8: ......

Page 9: ...s again OdorizerManagementOverview Main Reports and Setup are the three menu options on the top toolbar Select one to see drop down options From the mobile app select the to access the menu options fo...

Page 10: ...nit on a map so technicians or other employees can locate it o Hardware Parameters Configure a 4 20mA odorant sensor level sensor or other signal so it can be viewed and logged via YZ Connect o Suppor...

Page 11: ...eral Basic configuration of the device This will be configured by your company admin and should not need to be adjusted once set ID This number is the device ID When requesting support this number wil...

Page 12: ...erformance data for the NJEX odorizer on this page View pressures odorant level Verometer level serial totalizers stroke count and more USER level will see the User Snapshot which is the same as the b...

Page 13: ...ction rates pressures odorant level Verometer level pump performance totalizers flow signal serial and more USER level will see the User Snapshot which is the same as the below but without any of the...

Page 14: ...AlarmLog View the date and time when an alarm occurred and cleared Filter by date as necessary EventLog View key events and when they happened Filter by date as necessary...

Page 15: ...nges that were made to the unit It will highlight the most recent parameter change by default View the historical change log by changing the view to History Select two historical points to compare wha...

Page 16: ...opped in order to make changes In order to update parameters users must be ADMIN level or higher USER level cannot update parameters To update a parameter 1 Stop the odorizer 2 Adjust the parameter 3...

Page 17: ...This could be used to monitor a flow signal odorant sensor etc depending on the use case Setup 1 Add a hole for a NEMA 4X or IP67 rated cable gland in the YZ Connect box on the same side as the Anten...

Page 18: ...ilter parameters to graph via the drop down for Graphing Value View all the data individually or in a common graph Single view o When viewing all the data in a single view Click the parameter check bo...

Page 19: ...see the individual values at that time stamp Select the 3 bar icon in the upper right for download and print options Tabular YZ Connect data can be viewed in a table format for filtering and easy exp...

Page 20: ...ail and SMS Select users already setup in YZ Connect to get emails or text messages whenever a global alarm is triggered on the unit Each user can have two emails and a cell phone in their user settin...

Page 21: ...r to setup escalation 1 or 2 the user must have a cell phone number setup in YZ Connect Keeping an alarm from escalating When the user receives a text message they can respond with the code given in t...

Page 22: ...e the NJEX or ZEO manual if necessary After making any changes click to see if the indicator changes color Icon Meaning Action Indicates the device is online and communicating with the servers Indicat...

Page 23: ...wnload 5 Delete Message State 4 5 and 6 messages can be deleted 6 Flag the desired message from the details window and click delete 7 The icon should now be green again without the red border In the e...

Page 24: ...use 2 factor authentication to protect the logins of our users If it s the 1st time logging in on a device then YZ Connect will prompt the user for a code sent to the user logging in Why does my devic...

Page 25: ...www yz connect com Page 21 of 25 APPENDIX A Panel Control Drawing...