User Manual for YZXStudio ZY1270 

 
Please read the user manual carefully before using.   
CAUTION:    Don’t  calibrate  the  Voltage  and/or  Current  benchmark  unless  you have  the  professional  high-accuracy 
equipment. 
 
Technical Specification:   
Model: ZY1270   
Firmware Version:    3.0 
Input Voltage Range: DC 4-24V 
Input Current: Continuous -3A to 3A 
Voltage Resolution: 0.0001V 
Current Resolution: 0.0001A 
Ah/Wh Range: 0-99999Ah

0-99999Wh 

Ah/Wh Resolution: 0.0001Ah

0.0001Wh 

Accuracy: Voltage 0.2%+2d

Current 0.1%+2d

   

Display Screen: 1.3 inch 128*104 FSTN LCD Display 
Screen Refresh Frequency: 3 times/second 
Quiescent Current: 6mA (10mA with Backlight) 
Resistor of Current Sampling: 12mΩ 
Circuit Resistance: 42mΩ 
Memory Type:    Ferroelectric FRAM 
Rewrite Cycle: 10 Billion Times 
Recording  Pattern:  To  record  once  Ah/Wh  changed  + 
Load Balancing 

 
Operation Instruction 
Totally 6 operating modes, which can be shift from one to another by clicking the button.   

Mode 1    To test Voltage, Current, the Ah, Wh and Temperature of the Current Ah/Wh recording group (currently 
group 0 as shown in the pic middle right) 

 

Ah/Wh Recording Group(s):   
1.

 

Totally 6 recording groups available, indicated by number from 0 to 5. 

2.

 

To shift among the recording groups, Press and Hold the button for 2 
seconds and release once the group number changed. 

3.

 

To clear the Ah data of current recording group, Press and Hold the button 
for 5 seconds and release once the Ah data being zeroed. 

Mode 2    To test Voltage, Current, Power, Resistance and Temperature of Current Ah/Wh recording group 
(currently group 0 as shown in the pic middle right) 

 

Power of Load and Equivalent load resistance:   
1.

 

Totally 6 testing groups available, indicated by number from 0 to 5. 

2.

 

To shift among the testing groups, Press and Hold the button for 2 seconds 
and release once the group number changed. 

Mode 3 To test Micro Resistance value and voltage drop through charging cable 

                                                     

In-time Voltage   

Temperature 

                                                                                  Testing Group 

Current                                                           

                                                Reference Voltage and Current Value 

Resistance, and voltage drop 

Current Recognition Type 

Testing Method: 
1.

 

Connect the meter between the adapter/power bank and the constant current load, so as to get the Reference 
Voltage and Current Value 

2.

 

Keep the constant current load on meter, unplug the meter and load combo from the adapter/power bank, 
connect the target testing cable(micro USB type) between the adapter/power bank and the meter and load 