background image

Camera Calibration  
for Z CAM E2 & Z CAM E2 Flagship Series 

Introduction 

Camera calibration will check and calibrate the sensor of the camera as to fix 
some issues like hot pixel. It’s not listed in the menu but you can activate and 
run it with instructions below.  

This  function  is  available  for  Z  CAM  E2  and  Z  CAM  E2  flagship  series  from 
firmware 

0.95

.  

Preparation 

Please follow the instructions below before the camera calibration: 
  
1. Connect the camera with power adapter, and make sure the power supply 

will not stop during the operation. DO NOT use battery! 

 

2. Remove  the  lens  (if  any)  and  put  on  the  lens  mount  cover.  Make  sure 

there is no light coming into the camera. 

  

 

3. Remove ALL the connections including HDMI, USB and Ethernet, and just 

use the camera body. 

4. Disconnect any mobile control from mobile device or computer. 

Reviews: