The regulator is operated by pulling the cap up until it clicks, then turning it clockwise for
increased pressure, and counter-clockwise for decreased pressure.  The pressure can be
read off the gauge behind the regulator.  Pushing the cap back down again, locks it.

Operation and Safety Notes:

 

Take care in lifting and tightening the hood over the work area.  If the hood is not
tightened properly, it can result in its closing unexpectedly.

 

Take care when using the air gun needles, some of them have fine points and can cause
damage to people as well as be easily bent and damaged themselves.

 

Do not block the fan/air holes on the left and right side of the machine.  Blocking these
will diminish the performance of the machine.

 

Be sure to close the hood and have the vacuum hose attached when depowdering parts.

 

Check the filters in the back of the machine periodically to ensure they do not appear
over-saturated.

 

Check the vacuum bag periodically.  Change as needed.  This will enhance the
performance of the vacuum.  (NOTE: a full vacuum bag can be very heavy, and awkward
to get out of the vacuum, it may be better to not let the bags fill completely).

 

Do not aim the air gun at any person.

 

Do not depress the air gun continuously to depowder.  The compressor will work better if
the gun is depressed for only short intervals.  This allows a higher pressure to be
maintained consistently and avoids risk of overheating.

 

DO NOT OPEN THE ELECTRONICS PANEL COVER ON THE BACK OF THE
MACHINE.  There is nothing in regular maintenance that requires you to do so.  There is
a RISK OF ELECTRICAL SHOCK on some of the components located on the electronics
panel.