230 Volt ZD4 System:

Power Inlet: 

 Connect, using one of the detachable power cord supplied with the system, to

a standard wall outlet.  The ZD4 System requires 230 +/- 10% Volts AC 50Hz, 8 Amperes
maximum.  Replacement power cords are available from Z Corporation, contact your
customer service representative.

Main Power Circuit Breaker:

 This system uses an 8 Amp circuit breaker.  If this breaker

should ever switch, it may indicate a serious problem with your ZD4 System.  Please contact
Z Corporation customer service.  (If the breaker has switched, the small switch button will
show white).

1.3. 

SYMBOLS USED

The following symbols are used on the ZD4 System:

This is the international symbol for ‘warning’ or ‘caution’.  It indicates the need to

consult your manual for further information.  This symbol is in one place on the
ZD4 System.  It is used on the rear, lower, left to call your attention to the fact that
there is a risk of shock at the power inlet.

This is the international symbol for ‘ground point.’  It indicates that the line in

power is grounded to the cabinet through the stud near this point.  It is located in
the inside, on the floor of the cabinet, near the power inlet box.

1.4. 

SYSTEM SPECIFICATIONS

ZD4 System dimensions: 

24” x 24” x 59” high (61cm x 61cm x 150cm high)

ZD4 System weight:  

120 Volt system: 190 lb (86kg)

230 Volt system: 190 lb (86kg)

Power Requirements and operating conditions at Site of Installation:

Power requirements for 120V Systems

:

  120V ±10%, 60Hz, 11 Amps (15 Amps peak) for the for the Z

D4 System

Power requirements for 230V Systems

:

  230V AC ±10%, 50Hz, 8 Amps peak for Z

D4

 

 System

Operating conditions

: 68 to 85ºF, 20 to 60% Relative Humidity, non-condensing.

 