STARTING 

1.  Drain any water in the fuel tank (when 
necessary) and fill with oil 

2.  Check overflow protection – push down 
and ensure the level returns to position 
and there is a ‘click’ 

3.  Open the top of the heater and remove 
all accessible components and clean 
thoroughly 

4.  Check the burner pipe from the oil feed 
line is pushed fully into the combustion 
chamber 

5.  Plug into the power supply 

6.  Ensuring the heater is cool, pour 250 
ml of heating oil or diesel into the pan 

7.  Light the oil with paper or rag 

8.  Reassemble the ring, deflector and 
cylinder 

9.  Close the lid of the heater 

10. Press the “START” button 

11. After 10 – 20 minutes the activation 
thermostat will start the blower fan, 
combustion fan and oil pump. The heater 
will automatically run initially on low setting 

12. After 30 minutes the heater will 
automatically revert to the output level set 
on the power output control and you will 
be able to vary this 

 

STOPPING 

Press the “STOP” button on the control 
panel. The pump will stop and the green 
LEDs will turn off. The fan will continue to 
operate until the heater has cooled down 
to below the activation temperature. 

 

SAFETY CUT-OUT & RESET 

The heater will stop as above if either the 
overheat thermostat or overflow switch are 
triggered. 

To clear the overheating signal and return 
to normal operation, wait until the furnace 
is cooled down and the fan is switched off 
then press the push-button overheat 
thermostat to reset. 

Press “STOP” to turn off the LED 
signalling ‘overheat’ and then start as 
normal. 

To restart after overflow, ensure the 
heater has fully cooled and clear up any 
excess oil in or around the chamber. Then 
empty the overflow catch pan and press 
“STOP” to turn off the LED signalling 
‘overflow’ and then restart as normal.  

 

      

WARNING 

Never

 attempt to add oil directly into the 

chamber or relight whilst the heater is still 
hot. Vapours may cause explosion or 
burns. Wait for the heater to fully cool 
down first. 

Never 

try turn off the power to stop the 

heater. Use the “STOP” button so the 
heater can cycle through it’s cool down 
process. Remember the vaporising pan 
and other parts will stay hot after the 
heater has been switched off. 

 

MAINTENANCE 

DAILLY 

  Clean the combustion chamber 

and all internal parts  

  Check the oil overflow drain point 

is clear 

WEEKLY 

  Clean the combustion chamber 

base 

  Check the combustion chamber air 

inlet holes are clear 

  Check and clean the oil feed line 

and pipe 

MONTHLY 

  Clean the fuel tank and check oil 

pump filter 

Summary of Contents for ZM-135T

Page 1: ...ZMH Ltd t a Z M Heaters www zmheaters co uk T 00 44 0 333 600 44 60 Installation Operating Manual ZM 135T 18 35kW Universal Oil Heater...

Page 2: ...ustion chamber lid 3 Oil feed line 4 Activation thermostat 5 Control panel pump motor 6 Fuel tank 7 Cylinder Dfdfdfdsfd Dfdfffdfdf Dfdfdf 8 Deflector 9 Wire ring 10 Combustion chamber 11 Vaporising pa...

Page 3: ...The top of the flue should be above roof line apex where possible Run vertically where possible If this is not possible then use 45 elbows to exit walls Keep the non vertical section as short as possi...

Page 4: ...om the heater min 2m Keep spare fuel in safe containers away from sources of heat Use on level non combustible surfaces only Do not use near flammable liquids gases solids dust or compressed gas cylin...

Page 5: ...ORAGE CONDITIONS Please store in a clean dust free environment with temperature 20 to 85 C and humidity 5 85 and pressure 800 1200 hPa USAGE CONDITIONS Please ensure conditions as above except tempera...

Page 6: ...er is at operating temperature Pump 3rd green LED shows the fuel pump is operating Overheat red LED failure mode Overflow red LED failure mode START button should be pressed immediately after lighting...

Page 7: ...w the activation temperature SAFETY CUT OUT RESET The heater will stop as above if either the overheat thermostat or overflow switch are triggered To clear the overheating signal and return to normal...

Page 8: ...ZMH Ltd t a Z M Heaters www zmheaters co uk T 00 44 0 333 600 44 60 WIRING TO CONTROL PANEL...

Reviews: