Doc# 27-0002UM Issued 7/99 Rev. 1.2
Shock
15 G, 11 mS Operating 30 G,
11mS Nonoperating Bench handing
per MIL-STD-810E
Vibration, Random
3.0G RMS, 20-2,000 Hz Operating
4.0G HMS, 20-2,000Hz Nonoperating
Enclosure
NEMA 4/12 at front panel
Weight
24 lb.
Sand and Dust
5.5 M.P.H. for 25 minutes
Rain
Per MIL-STD-810E, method 506.3,
procedure II
Fungus
Non Nutrients/contaminants
Regulatory
EM/RFI
FCC Class A, MIL-STD-401 (optional)
Safety
(Pending Approval) FCC Class A: UL
1950
Reliability Specifications
Mean-time-between-failure (MTBF)
20,000 hours (Bellcore)
Operating Life
10 years without major overhaul
Quality Assurance
Complies with MIL-1-45208 and MIL-
Q-9858
Maintainability MTTR
<30 minutes or less
Developmental Options
Touch panel
28 VDC operation
Elapsed time meter
Customer specified mounting
Interchangeably power supply
29
Specifications
Summary of Contents for 15