4  By button 4 or double clicks of buttons 3 and 4   (max 8 nodes) 

The  IP  gateway  that  will  receive  the  scene 
activation  commands  must  be  placed  on  all 
association groups. 

Set and unset associations to actuators 

Associations can be assigned and removed either via Z-
Wave commands or using the device itself. 

To control a Z-Wave device from the Key Fob, the Node 
id of this device needs to be assigned to one of the four 
association groups. This is a three-step process: 

1.  Turn  the  Key  Fob  into  management  mode  and  hit 

button  4  within  10  sec.  (LED  is  blinking  green  when 
management mode is reached). 

2.  Within  10  sec.  push  the  button  of  the  Key  Fob  you 

like  the  Z-Wave  actuator  to  be  controlled  with.  After 
10 sec. the devices goes back to sleep. 

Single  click 

means  adding  to  this  association  group,  double 
click  means  removing  the  node  selected 

in  step 

(3) from this association group. 

3.  Find  the  Z-Wave  actuator  you  like  to  control  by  the 

device. Hit the button on the device to issue a Node 
Information  Frame  within  20  sec.  A  common  way  is 
hitting  a  control  button  one  or  three  times.  Please 
consult the manual of the device to be controlled for 
more  information  how  to  issue  a  Node  Information 
Frame. Any button press on Key Fob at this stage will 
terminate the process. 

Configuration Parameters 

Z-Wave products are supposed to work out of the 
box after inclusion, however certain configuration 
can adapt the function better to user needs or 
unlock further enhanced features. 

Pair Mode for Button 1 and 3  
(Parameter Number 1) 
Pair Mode for Button 2 and 4  
(Parameter Number 2) 
 
 

Value  Description 

Separately  

In pair without double clicks (Default) 

In pair with double clicks 

 
  

Control Commands on Group 1  
(Parameter Number 11) 
Control Commands on Group 2  
(Parameter Number 12) 
Control Commands on Group 3  
(Parameter Number 13) 

Control Commands on Group 4  
(Parameter Number 14) 
 

 

Value  Description 

Disabled 

Switch On/Off and Dim (send Basic Set and Multilevel)  
(Default) 

Switch On/Off only (send Basic Set) 

Switch All 

Send Scenes 

Send Preconfigured Scenes  

Control devices in proximity 

 
Typical click timeout  
(Parameter Number 20) 

Typical time used to differentiate click, hold and 
double click 
 

Value 

Description 

1 — 100  in 10ms units (Default 50) 

 
 

Send the following Switch All commands  
(Parameter Number 21) 

 

Value  Description 

Switch off only (Default) 

Switch on only 

255 

Switch all on and off 

 

Invert buttons  
(Parameter Number 22) 

 

Value  Description 

No (Default) 

Yes 

 

LED confirmation mode  
(Parameter Number 24) 

This allows saving battery power 

 

Value  Description 

No confirmations 

Confirm button press 

Confirm button press and delivery (Default) 

 

Send unsolicited Battery Report on Wake Up  
(Parameter Number 30) 

 

Summary of Contents for KFOB2

Page 1: ...y communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter Z Wave differentiates between Controllers and Slaves Slaves are either sensors S trans mitting metered or measured data or actuators A capable to execute an action Controllers are either static mains powered controllers C also ref...

Page 2: ...respective chapters below Button 3 Standard Inclusion Exclusion Mode The device is included or excluded from a controller in direct wireless range Any button press stops the mode Performing an exclusion of the device from a network resets the device into its factory default Button 4 Association Set To assign target devices to one of the four association groups Refer to the manuals section about as...

Page 3: ...Control of associated devices using ON OFF DIM UP and DIM DOWN This is the default mode No 1 Devices in association groups are controlled using Basic ON and OFF commands and Dim Start Stop commands This mode implements the communication pattern 7 The parameter value No 2 disables the use of Dim commands Control of Devices in proximity Basic ON OFF and Dim Start Stop commands are sent to the device...

Page 4: ... minimum allowed wakeup time is 240s but it s strongly recommended to define a much longer interval since the only purpose of a wakeup should be the reporting of the battery status or an update of the child protection settings Defining Node id of 0 as a destination of the Wakeup Notification will disable the periodical wakeup function entirely It is possible to set the node ID to 255 to send wakeu...

Page 5: ...nate the process Configuration Parameters Z Wave products are supposed to work out of the box after inclusion however certain configuration can adapt the function better to user needs or unlock further enhanced features Pair Mode for Button 1 and 3 Parameter Number 1 Pair Mode for Button 2 and 4 Parameter Number 2 Value Description 0 Separately 1 In pair without double clicks Default 2 In pair wit...

Page 6: ...llation costs removal cost or reinstallation cost For information on additional devices please visit us online This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can ...

Reviews: