CONTROL
The thermostat is controlled by three touch sensitive capacitive
buttons.
You only need to touch lightly to activate the buttons.
• Left (Up)
• Center (Confirm)
• Right (Down)
INCLUSION/EXCLUSION
To include the thermostat to your home automation gateway,
press Center (confirm) for 10 seconds.
The display will show OFF. Press Right (down) 4 times till you see
Con in the display.
Now start add device in your home automation software.
Start inclusion mode by pressing Center (confirm) for
approximately 2 seconds. The inclusion/exclusion icon will
appear in the display.
Confirmation will show Inc/EcL in the display.
If inclusion fails, Err (error) will appear.
Leave programming mode by choosing ESC in menu. Your
thermostat is ready for use with default settings.
PROGRAMMING YOUR THERMOSTAT
To activate the programming mode, press Center (confirm) for
10 seconds. Now the display will show OFF.
Now you are in programming mode. To scroll up and down
in the menu use button 1 and 3 (left and right) to navigate. To
enter submenu press Center (confirm). Always confirm your
setting by pressing Center (confirm) for 2 seconds.
Menu:
OFF
Turns the thermostat off.
A
Sensors:
A
Air/room sensor
AF
Air+Floor sensor
A2
External room sensor
A2F
External room Floor sensor
P
Power regulator
FP
Floor Power regulator
F
Floor sensor
SEn
Select the right Ohm value for your external/floor sensor.
NTC type (10, 12, 15, 33 or 47kΩ). Default 10kΩ.
CAE
Calibration for external sensor.
CAF
Calibration for floor sensor.
CAR
Calibration for room sensor.
br1
Brightness of display can be adjusted in this menu.
Con
Activation of inclusion/exclusion mode.
diF
Hysteresis
ALo
Setting lowest allowed temperature (limitation).
(Airsensor)
AHI
Setting highest allowed temperature (limitation).
(Airsensor)
FLO
Setting lowest allowed temperature (limitation).
(Florsensor)
FHI
Setting highest allowed temperature (limitation).
(Floorsensor)
ESC
Escape – go out of programming menu.
PRODUCT INFO
Heatit Z-Wave
TECHNICAL DATA
Rated voltage:
230V 50/60Hz
Max load:
3600W (resistive load)
750W self-limiting heating cable
Max current:
16A
Power consumption:
1,5W
Power regulator:
Time cycle 0-30min
Min/max installation temp: -20°C to 40°C
Min/max operating temp:
5°C to 40°C
Temperature intervals:
Floor sensor 5°C to 40°C
External room sensor 5°C to 40°C
Hysteresis:
0,3°C to 3,0°C (default 0,5°C)
Sensor values:
0°C
29,1 kOhm
10°C
18,6 kOhm
15°C
15,1 kOhm
20°C
12,2 kOhm
25°C
10,0 kOhm
Switch:
Single-pole switch
IP class:
IP21
TERMINAL
Use 1,5mm² or 2,5mm² according to load.
INCLUDED IN PACKAGE
Floor sensor 3 meters, Art. no. 5430109
WARRANTY
2 years
The thermostat is designed for electrical heating.
Thermo-Floor AS tar forbehold om typografiske feil,
andre feil eller mangler i vår informasjon.
Alle elektriske installasjoner skal
utføres av autorisert installatør.
Produktet skal installeres og dokumernteres ihht
gjeldende utgave av NEK 400 og
installasjonsveiledning.
FEATURES
·
Floor sensor
·
External room sensor
·
Temperature limiter
·
Power regulator
·
Z-Wave Plus chip, 500 series
·
Weekly program
·
Setback mode via gateway
or pilot wire
·
7-segment LCD-screen
·
Can be used in connection
with different NTC-sensors
·
Lock mode/child lock
· Backlight
· Calibration
·
8 associations
ART. NO.
PRODUCT
COLOR
5430499
Heatit Z-Wave thermostat 3600W 16A
White RAL 9003
5430498
Heatit Z-Wave thermostat 3600W 16A
Black RAL 9011
5430311
Frame for Heatit
White RAL 9003
5430312
Frame for Heatit
Black RAL 9011
5430497
Cable for software update on thermostat
5430108
Floor sensor Ø3mm 6m NTC 10 kOhm
5430109
Floor sensor Ø4mm 3m NTC 10 kOhm
5430128
External room sensor NTC 10 kOhm
5430129
External room sensor, mini, NTC 10 kOhm
Thermo-Floor AS l Østre Totenvei 24, NO-2816 Gjøvik, NORWAY