background image

IP Rating

IP 20

Frequency

868.42 MHz

Explorer Frame Support No

SDK

Device Type

Portable controller

Generic Device Class

Remote Controller

Specific Device Class

Portable Remote Controller

Routing

No

FLiRS

No

Firmware Version

0.0

Explanation of Z-Wave specific terms

Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically 

Gateways, Remote Controls or battery operated wall controllers.

Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators 

and even remote controls.

Primary Controller — is the central organizer of the network. It must be a controller. There can be only one 

primary controller in a Z-Wave network.

Inclusion — is the process of bringing new Z-Wave devices into a network.

Exclusion — is the process of removing Z-Wave devices from the network.

Association — is a control relationship between a controlling device and a controlled device.

Wakeup Notification — is a special wireless message issued by a Z-Wave device to annonces that is is 

able to communicate.

Node Information Frame — is a special wireless message issued by a Z_Wave device to announce its 

capabilities and functions.

Disposal Guidelines

The product does not contain hazardous chemicals.

Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. 

Contact your local government for information regarding the collection systems available. If electrical 

appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and 

get into the food chain, damaging your health and well-being.

(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 9 

Summary of Contents for DUW 064459

Page 1: ...ings It is using the frequency of 868 42 MHz to realize a very stable and secure communication Each message is reconfirmed two way communication and every mains powered node can act as a repeater for...

Page 2: ...aneously The remote control can operate as a secondary control beside an IP Gateway however it is not possible from this device to activate scenes defined in the IP Gateway All scenes and control grou...

Page 3: ...imary controler into inclusion mode Press and hold the Iclusion button for 2 seconds The LED will flash green for a moment for confirmation Operating the device The D WI Remote Control can either buil...

Page 4: ...n group All On Off turns on or off all those actuators supporting this function and being configured accordingly The configuration is usually done using an IP Gateway Together with an IP Gateway The r...

Page 5: ...ication with the device is limited In order to communicate with the device a static controller C is needed in the network This controller will maintain a mailbox for the battery operated devices and s...

Page 6: ...the following steps Press and hold Assoc button for 2 seconds Press Off button of the group from which the device should be removed Send out a NIF with the device which should be removed Special Func...

Page 7: ...e network means that it is turned back into factory default status This process can also exclude devices from it s previous network For Exclusion of Z Wave devices from the remote controls network do...

Page 8: ...sible that a network update fails if the network was changed too much after the last update In this case the the device need to be reincluded Re Inclusion is similar to a normal inclusion Its just not...

Page 9: ...Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wirele...