background image

 

Version 0.1 

8 June 2011 

www.2myhome.eu 

class: 0x26 COMMAND_CLASS_SWITCH_MULTILEVEL  

The Multilevel Switch Command Class can used to control devices that can be set the a numerical value (most 

of the time a percentage). Examples are dimmers are curtain control devices. 

class: 0x63 COMMAND_CLASS_USER_CODE

 

The User Code Command Class is used to control devices that can obtain security codes from the user, using a 

keypad or similar input (like the BeNeXt TagReader).

 

class: 0x86 COMMAND_CLASS_VERSION

 

The Version Command Class can be used to obtain the version the firmware of a device.

 

class: 0x84 COMMAND_CLASS_WAKE_UP  

The Wake Up Command Class is used to configure devices that can ‘sleep’ (turn of power and RF). The myGate 

can set a periodic interval after which the device awakes and send checks if there is any new data available.

 

 

 

Troubleshooting  

 
Frequently Asked Questions 
 

Q

: The 

myGate

 won’t turn on. 

A

1

.  Please check if the power supply is connected correctly. 

 

2

.  Check if the power supply is working.  

 

Q: 

The 

myGate

 has no internet connection.  

A:

  

1. 

Please check if the modem/router has internet connection.  

 
Q: 

What can I use to control the myGate? 

A:  

1.  

You can use 

www.2myhome.eu

 website to connect with the 

myGate

 and control 

all devices. 

Summary of Contents for myGate

Page 1: ...tuses of the device as follows A Booting and checking firmware When power is applied the green and orange leds will blink while checking valid firmware After a few seconds the myGate is booted the ind...

Page 2: ...aken 1 Make sure that the myGate has no devices included if it has please exclude them first using the 2MyHome Graphical Web interface 2 Set the Primary Controller or an Inclusion Controller of the ex...

Page 3: ...fter which the myGate should be in the same state 1 Press and hold the Learn button the indicator light will switch off 2 Once the indicator light starts blinking orange release the button The indicat...

Page 4: ...perating temperature 10 C to 50 C Operating humidity 30 to 80 Detailed information myGate myGate is the central part of the home system It will be connected through a router directly to Internet The m...

Page 5: ...needs to include every product to the network 2myHome will step by step instruct how to do this And finally the configuration which was already made during the play try period will be send to the myGa...

Page 6: ...uent nodes in the network Being primary is just a role Any controller can be primary but only one controller can be primary at a time The primary controller manages the allocation of node IDs and gath...

Page 7: ...k class 0x70 COMMAND_CLASS_CONFIGURATION The Configuration Command Class is used to configure or read out the current operation state of the myGate 1 Current Lifestyle Description Obtain Change the cu...

Page 8: ...is will report information about the manufacturer This product will contain the manufacturer ID of BeNeXt Manufacturer ID of BeNeXt is 138 the ID of this product is 1 class 0x8F COMMAND_CLASS_MULTI_CM...

Page 9: ...ss 0x26 COMMAND_CLASS_SWITCH_MULTILEVEL class 0x63 COMMAND_CLASS_USER_CODE class 0x86 COMMAND_CLASS_VERSION class 0x84 COMMAND_CLASS_WAKE_UP class 0x71 COMMAND_CLASS_ALARM The Alarm Command Class is u...

Page 10: ...COMMAND_CLASS_POWERLEVEL The Powerlevel Command Class is used to check the connection quality between two Z Wave devices class 0x75 COMMAND_CLASS_PROTECTION The Protection Command Class can be used t...

Page 11: ...Class can be used to obtain the version the firmware of a device class 0x84 COMMAND_CLASS_WAKE_UP The Wake Up Command Class is used to configure devices that can sleep turn of power and RF The myGate...

Reviews: