Z-Wave Heating Thermostat SR-ZV9092A

09.ZV9092A.04770

Function introduction

Important: 

Read All Instructions Prior to Installation

Front side

Product Data

F

TIME/SHIFT button, to set 

time schedule of the 

device quickly and move 

the cursor

Function button, to 

confirm, save setting

Mode button, to switch 

operation modes and quit

Move up and move down 

buttons

LED Display

59 mm

80 mm

59 m

m

80 m

m

10 mm 10 mm

31 mm

Back side

NTC

L    L   N   N

AC Power input

Floor temp sensor

Output

Home Interface

SR-ZV9092A

Z-Wave Frequency

868.42MHz (EU)

Input Voltage

EU: AC200-240V, 50/60Hz

Output Voltage

EU: AC200-240V

Max Load

3680W @ 230V (resistive load)

Max Current

16A

Power Consumption

<2W

Ambient Temperature

0°C to 40°C (during operation)

Set Temperature Range

Hysteresis

0.5°C to 2°C (default 0.5°C)

Floor sensor type

Control Mode

OFF, HEAT, ENERGY HEAT

AWAY, DRY

Control Type

Wiring Requirement

IP Rating

IP21

Relative Humidity

8% to 80%

Dimensions

80x80x52mm

Approvals

0°C to 40°C  

1. NTC/10K B(25/50 )=3950 (default)

2. NTC/15K B(25/50

)=3950

3. NTC/50K B(25/50

)=3950

4. NTC/100K B(25/50

)=3950

Control type means which temperature sensor the device refers to 

when it adjust temperature.

Room sensor

: adjust temperature refers to room temperature 

(factory default type).

Floor sensor

: adjust temperature refers to floor temperature.

Room+Floor sensor

: adjust temperature refers to both room 

temperature and floor temperature.

Current 

≤ 

13A - 1.5mm² solid core wire

Current > 13A to 16A - 2.5mm² solid core wire

 

Z-Wave Plus

CE

,

LVD

: EN 60730-1:2016;A1, EN IEC 60730-2-9:2019;A1

EMC & RF

: EN IEC 61000-3-2:2019, EN 61000-3-3:2013+A1:2019,

EN 60730-1:2016+A1:2019, EN 60730-2-

19:2019+A1:2019+A2:2020, EN 50663:2017;ETSI EN 301 489-

1V2.2.3, ETSI EN301 489-3V2.1.1

ETSI EN300 220-1 v3.1.1., ETSI EN300 220-2 V3.2.1

RED certificate

: 2014/53/EU

• 

The Z-Wave HVAC controller is a wireless thermostat for heating system, which complies to Z-Wave Plus 

wireless protocol standards. The thermostat has 4 operation modes which can be controlled manually and 

locally or through remote controlled through Z-Wave primary controller (gateway).

Control Pollution Degree (Method D)

pollution degree 2

Rated Impulse Voltage (Method D)

4kV

Summary of Contents for SR-ZV9092A

Page 1: ...50 3950 default 2 NTC 15K B 25 50 3950 3 NTC 50K B 25 50 3950 4 NTC 100K B 25 50 3950 Control type means which temperature sensor the device refers to when it adjust temperature Room sensor adjust tem...

Page 2: ...he device is under idle status Manual Comfort Mode the device will control the heating system according to current set temperature The temperature can be set by move up and move down button on the Hom...

Page 3: ...ersis enables the controller to control the relay only when the sensor temperature is a little bit lower than the set temperature this value can be set This hysterersis only valid when the control typ...

Page 4: ...de After scanning to add the device reset power of the device or waiting for a while the device will be added to the gateway automatically Please find the QR code on the casing of the device Removing...

Page 5: ...TAT_HEATING Always On Slave AOS Yes 2 Technical Specifications SENSOR MULTILEVEL Type support Air temperature Scale Celsius Z Wave Technical Specifications 1 Supported Notification Repoert and Sensor...

Page 6: ...Set 5 AGI_CONTROL_KEY01 0x2001 Transfer Command Class THERMOSTAT_SETPOINT_SET THERMOSTAT_MODE_SET to control other temperature control devices when operation changes EndPoint01 1 Lifeline AGI_LIFE_LI...

Page 7: ...be away from sunlight and sources of direct heat We recommend installing the device approximately 1 5 meters above the floor Troubleshooting 1 External floor sensor temperature tolerance is too big Po...

Reviews: