1) Release front cover by inserting a flat screw-driver into side crack

3) Mount back part into junction box, then screw the thermostat in

2)

 

Release the frame

4) Re-install the frame and the front part in sequences

Installation

2. Remove the display unit and backplate of the device from the packaging.
3. FIRST ENSURE THE POWER IS OFF at the main circuit breaker, and then test the wires with a probe or multimeter to verify. 
Insert the power and heater wires to the correct device terminals by inserting a small Phillips-head screwdriver in the slot beneath 
each terminal to open. Follow the connection diagram and instructions below:

• Power wires:

 connect Line & Neutral wires to L & N terminals labeled “IN”

• Heater wires:

 connect Line & Neutral wires to L & N terminals labeled with “heating element” graphic

WARNING: The wire size shall be in compliance with regulations, using wire with insufficient size for big load will cause 
severe temperature rising.  

This device should be installed by a licensed electrician in a manner that conforms to local regulations and building codes. 
Provide these instructions to the licensed electrician who is installing the device.

WARNING: Electrical power must be switched off during installation.  

1. Placement of the device is of utmost importance for proper operation and must be away from sunlight and sources of direct 
heat. We recommend installing the device approximately 1.5 meters above the floor.

Troubleshooting:

1. External (floor) sensor temperature tolerance is too big

   Possible reason: the selected sensor type is not correct

2. The gateway can not set temperature when energy save mode is selected

   The temperature schedule (parameter 8) of auto mode (energy save mode) is not configured correctly

3. Current temperature is not executed when away mode is selected

   Check whether away mode time is set as 0 or within valid time range

4. Over heat alarm when power on the device

   Possible reason: the set sensor type is not correct or sensor type after factory reset is not correct

5. Device time is not the same as the gateway controller after included to the network

   Set the device time and time zone manually after included to the gateway network

6. The tolerance of the indoor temperature sensor is high after powered on

   Possible reason: due to temperature effect, we need to wait for a while

Wiring diagram

NTC

L    L   N   N

L

   

N

Floor temp

sensor

Connection diagram 2

SR-ZV9092A

Window open detect function temperature threshold: the Celsius degrees that the 

temperature decreases within 3 minutes, unit is 0.5 Celsius degree.  

0, disbaled

3-8, the set temperature threshold

0x18(24)

1

0

Other Set

0x1A(26)

1

0

Monitor Set

The time zone that the time parameters command adopts is UTC, the time zone 

need to be set: 

+12 ~ -12

NTC

L    L   N   N

SR-ZV9092A

L

   

N

Connection diagram 1

Floor temp

sensor

Summary of Contents for SR-ZV9092A

Page 1: ...50 3950 default 2 NTC 15K B 25 50 3950 3 NTC 50K B 25 50 3950 4 NTC 100K B 25 50 3950 Control type means which temperature sensor the device refers to when it adjust temperature Room sensor adjust tem...

Page 2: ...he device is under idle status Manual Comfort Mode the device will control the heating system according to current set temperature The temperature can be set by move up and move down button on the Hom...

Page 3: ...ersis enables the controller to control the relay only when the sensor temperature is a little bit lower than the set temperature this value can be set This hysterersis only valid when the control typ...

Page 4: ...de After scanning to add the device reset power of the device or waiting for a while the device will be added to the gateway automatically Please find the QR code on the casing of the device Removing...

Page 5: ...TAT_HEATING Always On Slave AOS Yes 2 Technical Specifications SENSOR MULTILEVEL Type support Air temperature Scale Celsius Z Wave Technical Specifications 1 Supported Notification Repoert and Sensor...

Page 6: ...Set 5 AGI_CONTROL_KEY01 0x2001 Transfer Command Class THERMOSTAT_SETPOINT_SET THERMOSTAT_MODE_SET to control other temperature control devices when operation changes EndPoint01 1 Lifeline AGI_LIFE_LI...

Page 7: ...be away from sunlight and sources of direct heat We recommend installing the device approximately 1 5 meters above the floor Troubleshooting 1 External floor sensor temperature tolerance is too big Po...

Reviews: