time. 8 seconds per tick, and minimum
time is 24 seconds, default tick is 3 (24
seconds).
Setting the suitable value to prevent
received the trigger signal too frequency.
Also can save the battery energy.
Notice:
If this value bigger than the
configuration setting
NO. 9. There is a
period after the light turned off and the
PIR not detecting.
9 Turn Off Light
Time
4
4~127
After turn on the light, setting the delay
time to turn off the light when the PIR
motion is not detected. 8 seconds per
tick, and minimum time is 32 seconds,
default tick is 4 (32 seconds).
10 Auto Report
Battery Time
12
1~127
The interval time for auto report the
battery level. 30 minutes per tick and
minimum time is 30 minutes, default tick
is 12 (6 hours).
11
Auto Report
Door/Window
State Time
12
1~127
The interval time for auto report the
door/window state. 30 minutes per tick
and minimum time is 30 minutes, default
tick is 12 (6 hours).
12
Auto Report
Illumination
Time
12
1~127
The interval time for auto report the
illumination. 30 minutes per tick and
minimum time is 30 minutes, default tick
is 12 (6 hours).
13
Auto Report
Temperature
Time
12
1~127
The interval time for auto report the
temperature. 30 minutes per tick and
minimum time is 30 minutes, default tick
is 12 (6 hours).
Z-Wave Supported Command Class
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_VERSION
COMMAND_CLASS_SENSOR_BINARY_V2
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_BATTERY
COMMAND_CLASS_BASIC
Specifications
Power by CR123A lithium battery.
Signal (Frequency):
868.42 MHz(EU),
908.42 MHz(US),
922~926 MHz(JP/TW)
Range:
Minimum 30 meters indoor,
70 meters outdoor line of sight.
Operating Temperature: -10
o
C ~ 40
o
C
For indoor use only.
Specifications subject to change without notice due to continuing
product improvement.
9