background image

Value

Description

0

Separately

1

In pair without double clicks (Default)

2

In pair with double clicks

Button 2 and 4 pair mode (Parameter Number 2, Parameter Size 1) In separate mode button 2 works with 
group 2, button 4 with groups 4. Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming 
Down. In pair button 2/4 are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single 
clicks works with group 2, double click with group 4.

Value

Description

0

Separately

1

In pair without double clicks (Default)

2

In pair with double clicks

Action on group 1 (Parameter Number 11, Parameter Size 1) In Switch On/Off only mode On command is 
sent on Dim Up, Off on Dim Down. In Scenes mode the scene ID sent is (10 * group + ActionID), where 
ActionID is: 1 = On, 2 = Off, 3 = Dim Up Start, 4 = Dim Down Start, 5 = Dim Up Stop, 6 = Dim Down Stop

Value

Description

0

Disabled

1

Switch On/Off and Dim (send Basic Set and Switch Multilevel) (Default)

2

Switch On/Off only (send Basic Set)

3

Switch All

4

Send Scenes

5

Send Preconfigured Scenes

6

Control devices in proximity

Action on group 2 (Parameter Number 12, Parameter Size 1) In Switch On/Off only mode On command is 
sent on Dim Up, Off on Dim Down. In Scenes mode the scene ID sent is (10 * group + ActionID), where 
ActionID is: 1 = On, 2 = Off, 3 = Dim Up Start, 4 = Dim Down Start, 5 = Dim Up Stop, 6 = Dim Down Stop

(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 7 

Summary of Contents for ZME_KFOB2

Page 1: ...cription 1 The Z Wave Me Key Fob is a 4 button Z Wave device that can both control other Z Wave devices and activate predefined scenes in a controller or IP Gateway Although it is controlling other de...

Page 2: ...of this network This process is called Inclusion Devices can also leave a network This process is called Exclusion Both processes are initiated by the primary controller of the Z Wave network This co...

Page 3: ...of associated devices with only On Off commands Devices are controlled using only Basic Set On Off commands On dimming Up event On is sent on dimming Down Off is sent This mode also implements commun...

Page 4: ...de MUST be turned on wirelessly However in protected by sequence mode it is possible to unlock the device for local operation by pressing any button within 5 sec The unlock state will last for 5 secon...

Page 5: ...he technical capabilities The inclusion and exclusion of the device is confirmed by sending out a Node Information Frame Beside this it may be needed for certain network operations to send out a Node...

Page 6: ...e within 20 sec A common way is hitting a control button one or three times Please consult the manual of the device to be controlled for more information how to issue an Node Information Frame Any but...

Page 7: ...n Off only mode On command is sent on Dim Up Off on Dim Down In Scenes mode the scene ID sent is 10 group ActionID where ActionID is 1 On 2 Off 3 Dim Up Start 4 Dim Down Start 5 Dim Up Stop 6 Dim Down...

Page 8: ...own Start 5 Dim Up Stop 6 Dim Down Stop Value Description 0 Disabled 1 Switch On Off and Dim send Basic Set and Switch Multilevel Default 2 Switch On Off only send Basic Set 3 Switch All 4 Send Scenes...

Page 9: ...ts Default 50 Send the following Switch All commands Parameter Number 21 Parameter Size 1 Value Description 1 Switch off only Default 2 Switch on only 255 Switch all on and off Invert buttons Paramete...

Page 10: ...ue Description 0 No Default 1 To same node as wake up notification 2 Broadcast to neighbours Technical Data IP Rating IP 20 Battery Type 1 CR2032 Frequency 868 42 MHz SRD Band Wireless Range up to 100...

Reviews: