42
Z21 XL BOOSTER
42
The configuration screen is structured very similarly to the configuration dialog via CAN. For a descrip
-
tion of the individual settings see above chapter "Configuration and Firmware Update via CAN and Z21
Maintenance Tool".
For more information, please refer to the latest Z21 Maintenance Tool operating instructions and the
operating instructions of the Z21 pro LINK.
Reset to Factory Settings
If it is necessary to reset all settings to factory state, hold down the STOP button until the status LED flas
-
hes violet (i.e., red + blue simultaneously). Then a reset to factory state is triggered and the track output is
automatically activated.
Status LED
In Operation:
Color
State
Meaning
Blue
on (bright)
Normal operation
with
CAN
and activated Auto Set-
tings, i.e., the settings (RailCom) are automatically taken
over from the Z21 via CAN.
Blue
on, slowly
alternating
between light
and dark
Normal operation
with
CAN
and deactivated Auto Set-
tings, i.e., the settings (RailCom) are NOT automatically
taken over from the Z21 via CAN.
The defaults settings of the booster are used.
Blue
on (dark)
Normal operation
with
B-Bus
,
CDE
, or via
CAN
with a
Z21 with older firmware < V1.23 without ZCAN20 stack
(firmware update recommended).
The defaults settings of the booster are used.
Blue
flashing
STOP
, track voltage off.
Red
flashing
Short circuit or overtemperature
With the STOP button held down:
Green
flashing
Configuration mode
Summary of Contents for XL BOOSTER
Page 23: ...23 DEUTSCH Z21 XL BOOSTER ...
Page 45: ...ENGLISH Z21 XL BOOSTER 45 ...
Page 67: ...FRANÇAIS Z21 XL BOOSTER 67 ...