16.0
SUMMARY OF OPTIONS
This section lists the different options that are available in the various menus.
16.1
The System Setup Tab
Parameter
Options (default in bold)
Notes
Local IP Setup
Local IP Address 192.168.x.y
(192.168.0.120)
Sets the IP address of the unit. Note that a “save”
of these settings and a reboot is needed for
changes to this value to take effect.
Local Netmask
255.255.z.w (
255.255.0.0
)
Sets the netmask of the unit. Note that a “save” of
these settings and a reboot is needed for changes
to this value to take effect.
Default Gateway 192.168.a.b (
192.168.0.1
)
Sets the network gateway to use for the unit.
Note that a “save” of these settings and a reboot is
needed for changes to this value to take effect.
DNS Server IP 1
a.b.c.d (
8.8.8.8
)
Used to specify the DNS server for hostname
lookup when in static IP mode.
DNS Server IP 2
e.f.g.h (
8.8.4.4
)
Used to specify the secondary DNS server for
hostname lookup when in static IP mode.
Use DHCP
Checked
Unchecked
Sets whether DHCP is used to dynamically obtain
an IP address at start up.
Device Setup
Auto Start
Checked
Unchecked
Check this box to set the system to automatically
start encoding upon powering on.
Advanced
Settings
Checked
Unchecked
Check this box for advanced encode settings to
appear on the channel tab.
Device Management
Set Device Name
Button
Sets a custom name for the camera to appear in
the user interface.
Set Password
Button
Sets a password to limit access to the user
interface.
Update device
firmware Button
Access the Software Updater to update the
firmware on your device. An image file of the
desired firmware is needed.
Download device
logs Button
Extract a set of diagnostic logs that can be
provided to Z3 in the event of an issue to be
reported. The resulting file is saved on the PC with
the user interface open.
Reboot Button
Restarts the unit without the need to disconnect
power.