15 Operation and Maintenance Manual
MQ-150 Ballscrew Feed Unit
Done (F3) -
Set tool to that which is being displayed
Jog to rapid -
Jog unit to end point of rapid travel (part should be
loaded, use slow mode near part)
Fast (F1) -
Selects fast jog, good for approaching part
Slow (F2) -
Selects slow jog, good for near part motion
Done (F3) -
Sets current location to rapid point
Skip (F6) -
Keeps existing value stored in memory without
overwriting with current position
Enter rapid rate -
Enter rate of rapid travel in Inches Per Minute
Enter full back position -
Enter position ahead of home sensor to
return back to after a cycle. This is an absolute position.
Enter # of drill stages -
Enter # of segments to drilling cycle (Ex.
entering drill point into part at one rpm and feed rate and drilling
through at a different rpm and feed rate = 2 drill stages)
Enter depth -
Enter
relative
depth for each drill stage. You will
be prompted for which drill stage you are entering data for.
Enter feed rate -
Enter feed rate for each drill stage in Inches Per
Revolution
Enter rpm -
Enter rpm for each drill stage
Enter tap pitch -
Enter tap pitch in inch or metric (tap units only)
Enter tap rpm -
Enter tap rpm
Enter tap hand –
Enter right or left hand tap(tap units only)
Enter dwell time -
Enter time in milliseconds to wait at bottom of
drilling depth (typically used for blind hole and spot face clean up)
Enter peck increment -
Enter relative depth of each drill peck
(peck drill tool only)
Tool properly set up, hit F2 to move to zero (F2) -
If a tool has
been successfully set up, hit F2 to move back to zero. This allows
another tool to be set up or allows running of a part.
Exit (F6) -
Exits back to MAIN MENU
Remote -
Put unit in run mode (waits for start buttons or PLC signal)
Enter tool number -
operator entry of tool number you wish to set up
Automatic mode, use start buttons or PLC
- Display screen
only, waiting for cycle start command
. Unit is enabled to run at
this point.
Exit (F6) -