5. Installation Guide

5. 1 Check for Leaks

Before installing the product on a PC, check each Water Block and the Reserator for leaks.

5. 2 Determine the Placement of the Reserator

The  Reserator’s  placement  should  be
determined  in  relation  to  the  position
of  the  PC.  Place  it  upright  next  to  or
slightly  above  the  PC.  Note  that  if  the
Reserator is placed lower than the PC,
the  PVC  tube’s  internal  air  pressure
may prevent proper initial operation.

5. 3 Install the CPU Water Block (ZM-WB4 Gold)

1) Refer to the manual included with the ZM-WB4 Gold for installation instructions.
2) If physical interference occurs while installing the Water Block, stop the installation.

5. 4 Install the VGA Water Block (ZM-GWB3)

1) Refer to the manual included with the ZM-GWB3 for installation instructions.

5. 5 Install the I/O Bracket

1) As shown in the diagram, install the I/O bracket on

a PCI slot on the computer case.

I/O Bracket should be installed at the lowest

possible slot.

((O

O))

((O

O))

((XX))

((XX))

((XX))

I/O Bracket

PCI Slot

Intel Pentium 4 

Socket 775 CPU

Intel Pentium 4 

Socket 478 CPU

AMD Sempron/AMD 64

Socket 754/939/940 CPU

Summary of Contents for RESERATOR1 V2

Page 1: ...and watch the RESERATOR 1 V2 installation video for an installation overview Pleasereadthismanualthoroughlybeforeinstallation Thespecificationsofthisproductanditscomponentsmaychangewithoutpriornotice...

Page 2: ...ys turn on the water pump first before using the system 3 If the coolant isn t circulating or the pump is making a strange noise turn the PC OFF immediately 4 Do not place any objects on the product 5...

Page 3: ...servoir radiator and water pump into one system for easy operation It is anodized and comes with a custom coolant to prevent corrosion The new CPU Water Block ZM WB4 Gold VGA Water Block ZM GWB3 and t...

Page 4: ...r allows simple installation 1 4 Northbridge Water Block ZM NWB1 Optional This anodized pure aluminum block is built for high performance cooling and is designedforcompatibilitywithawidevarietyofnorth...

Page 5: ...mensions 63 L x 63 W x 16 5 H mm 4 Compatibility Intel Pentium 4 Socket 775 478 AMD Sempron AMD64 Athlon 64 Athlon 64 FX Opteron Socket 754 939 940 2 3 VGA Water Block ZM GWB3 1 Weight 100 g 2 Materia...

Page 6: ...f any product may change without prior notice to improve performance 3 Installation Overview Reserator CPU Water Block ZM WB4 Gold VGA Water Block ZM GWB3 I O Bracket Flow Indicator Quick Coupling Nor...

Page 7: ...k ZM WB4 Gold 1SET Please refer to the separately provided manual for the ZM WB4 Gold 4 3 VGA Water Block ZM GWB3 1SET Please refer to the separately provided manual for the ZM GWB3 4 5 Coolant ZM G20...

Page 8: ...re aluminum block is built for high performance cooling and is designed for Motherboard compatibility with a wide variety of northbridge chipsets VGA RAM Water Block ZM RWB1 This VGA RAM Water Block i...

Page 9: ...air pressure may prevent proper initial operation 5 3 Install the CPU Water Block ZM WB4 Gold 1 Refer to the manual included with the ZM WB4 Gold for installation instructions 2 If physical interfere...

Page 10: ...omputer case 3 Connect a Quick Coupling Insert to the other end of the PVC Tube and clamp with a Tube Clamp 4 Plug the Quick Coupling into the Reserator s Base IN fitting 5 8 Connect the CPU Water Blo...

Page 11: ...the Quick Coupling to the Quick Coupling Body on the Reserator s Base OUT What does Quick Coupling do The Quick Coupling Sockets allow quick connection and disconnection while the incorporated valve p...

Page 12: ...ose ends 5 12 Fill the Coolant 1 Take off the Sink Cover on top of the Reserator 2 Fill with the provided coolant ZM G200 and two liters of distilled water Note 1 The provided coolant is a concentrate...

Page 13: ...bubbles 3 Check each fitting for leaks If there is a leak circuitry and other components may short circuit and malfunction so be careful 4 If there is a leak turn the pump off immediately wipe the are...

Page 14: ...Water Pump Separate the Fixing Plate and the Fixing Bolts by unscrewing the Fixing Bolts on the Sink Base with a screwdriver 3 Disconnect the Water Pump Power Switch Separate the Power Switch from th...

Page 15: ...e the Integrated Water Pump Pull the Water Pump off the Sink Base as shown in the diagram 8 Put on the Sealing Bolt B After removing the Cable Fitting screw on the Sealing Bolt B Fasten tightly If thi...

Page 16: ...e It is recommended that the installation is done in such a manner 1 When installing an External Water Pump confirm the coolant entrance and exit holes before connection 2 Check that the chosen water...

Page 17: ...osures that operate without the use of a fan TNN Computer Enclosures use the aluminum enclosure itself as a heatsink They are ideal for environments that require silence as well as for home theatre sy...

Page 18: ......

Reviews: