background image

The specifications of product may change without any prior notice to improve performance.

1

1. Safety Precautions

The following precautions and directions are measures against possible accidents and injuries.
Please read them thoroughly before using this product.

To ensure a safe and easy installation, please read the safety precautions above and the following
notes. 

Plugging the main power connector P1 into the motherboard while the product is connected to the

AC power source may cause damage to the motherboard.

Make sure that the connectors are connected to their designated locations, and that the connectors
are not oriented in the wrong direction when connecting the DC output connectors.
If the Power ON LED fails to light up when the main power button is pressed after completing the

installation procedure, some devices may be connected in incorrectly or the motherboard may be

faulty. 

Warning

Neglecting the following may cause serious
injury or death.

Opening the cover of the product while the power

cord is plugged into an outlet may cause electrocution
or critical damage to the product.

Handling the power cord with wet hands may cause

electrocution.

Inserting fingers or metallic objects into the cooling

fan may cause injury or electrocution.

Caution

Neglecting the following may cause minor injuries,
degrade product conditions or cause malfunction.

Operating the product in an extremely cold or hot
environment  can  degrade  product  performance
and lifespan. 

Liquids that enter the product may cause malfunction.

Operating the product in a humid or non-ventilated

environment may reduce product lifespan. 

3. Notes on Installation

1) One Power Supply

2) Two Cables for PCI-E

3) Three Cables for ODD/HDD

4) Three Cables for S-ATA

5) One Fan Dual-Connector (ZM-DC1)

6) One Power Cord for AC Power Source (Not included in some countries)

7) One User’s Manual 

8) Five Cable Ties

9) Four Power Supply Installation Bolts

2. Components 

Summary of Contents for ZM1000-HP

Page 1: ......

Page 2: ...e motherboard may be faulty Warning Neglecting the following may cause serious injury or death Opening the cover of the product while the power cordis plugged into an outlet may cause electrocution or critical damage to the product Handling the power cord with wet hands may cause electrocution Inserting fingers or metallic objects into the cooling fan may cause injury or electrocution Caution Negl...

Page 3: ...ates high frequency noise in standby mode The Standby Noise Filter Switch is NOT a power switch The AC Power Cord MUST be unplugged in order to turn the power supply OFF Six Independent 12VDC Outputs Six 12VDC rails supply power independently to the CPU VGA motherboard and peripheralcomponents for the highest level of stability and performance Four PCI Express VGA Power 6 Pin 6 2 Pin Connectors Fo...

Page 4: ...integrate more energy efficient power supplies into desktop computers and servers EZ Grip Connectors for ODDs HDDs EZ Grip Connector for easy removal of the plugs from ODDs HDDs Supports ATX12V CPU 4 Pin and EPS12V CPU 8 Pin Two ATX12V CPU 2 x 2 4 Pin power cables can be combined to form an EPS12V CPU 8 Pin power cable Gold Plated Terminals 16AWG Wires All connector terminals are gold plated to mi...

Page 5: ...angewithoutanypriornoticetoimproveperformance 4 5 Specifications Output Power Cable Specifications Cable Types and Function Using the Dual Connector ZM DC1 5V Connector 3 Pin Power Supply Peripheral Connector 12V ZM DC1 Fan Connector ...

Page 6: ...quency 47Hz 63Hz 115VAC 15A 230VAC 8A Active PFC 99 Maximum 115VAC 80A 230VAC 100A 86 Max 230VAC Full Typical load Vout Regulation Range 3 3VDC 5 3 14V 3 47V 5VDC 5 4 75V 5 25V 12V1DC 5 11 4V 12 6V 12V2DC 5 11 4V 12 6V 12V3DC 5 11 4V 12 6V 12V4DC 5 11 4V 12 6V 12V5DC 5 11 4V 12 6V 12V6DC 5 11 4V 12 6V 12VDC 10 10 8V 13 0V 5VSB 5 4 75V 5 25V DC Output ZM1000 HP Vout Output Load Rating Combined Imin...

Page 7: ...es in the following cases A Violation of the Safety Precautions and the Notes on Installation of this manual B Human fatality and or property damage due to events of natural causes C External case damage electrical problems and damage to components caused by careless mishandling Disclaimer Zalman Tech Co Ltd is not responsible for any damages due to external causes including but not limited to imp...