background image

Electrical & Physical Specifications

6. Zalman’s CNPS (Computer Noise Prevention System) Products

For  a  stable  and  noiseless  system  of  the  highest  quality,  use  Zalman’s  Ultra  Quiet  CPU
Coolers, Ultra Quiet VGA Coolers, Heatpipe HDD Coolers, Fanless Northbridge Coolers, and
Noiseless Case Fans.

U

Ullttrraa Q

Quuiieett C

CPPU

U C

Coooolleerr

FFaannlleessss N

Noorrtthhbbrriiddggee C

Coooolleerr

U

Ullttrraa Q

Quuiieett C

CPPU

U C

Coooolleerr

H

Heeaattppiippee H

HD

DD

D C

Coooolleerr

FFaannlleessss V

VG

GA

A C

Coooolleerr

AC Input Range

AC Input Range

(Rated)

PFC Type

Power Factor

Efficiency

Inrush Current Limit

(@ Cold start at 25

)

DC Output Voltage

Regulations

At Full

Load

At Full

Load

DC Output Ripple &

Noise

Voltage

100VAC ~ 240VAC 

±

10%

Frequency

47Hz ~ 63Hz

115VAC12A

230VAC5.5A

Active PFC

99% Maximum

115VAC60A

230VAC100A

86% Max, @230VAC, Typical load

Vout

Regulation Range

+3.3VDC

±

5%

+3.14V ~

+3.47V

+5VDC

±

5%

+4.75V ~

+5.25V

+12V1DC

±

5%

+11.4V ~

+12.6V

+12V2DC

±

5%

+11.4V ~

+12.6V

+12V3DC

±

5%

+11.4V ~

+12.6V

+12V4DC

±

5%

+11.4V ~

+12.6V

-12VDC

±

10% -10.8V ~

-13.0V

+5VSB

±

5%

+4.75V ~

+5.25V

DC Output

ZM750-HP

Vout

Output Load Rating

Combined

I

min

I

max

I

peak 

Power

+3.3V

0.8A

30A

160W

+5V

0.5A

30A

+12V1

0.5A

20A

+12V2

0.5A

20A

+12V3

0.5A

20A

720W 750W

+12V4

0.5A

20A

-12V

0.0A

0.8A

22.1W

+5VSB

0.0A

2.5A

3.5A

Ambient Temperature

Operation

10

~ +50

Stored

-20

~ +80

Ambient Humidity

Operation

5%RH ~ 95%RH

Stored

5%RH ~ 95%RH

Dimensions

165mm(L) 

*

150mm(W) 

*

86mm(H)

MTBF(25

)

100,000

hours

Protection

Over-Voltage Protection (OVP)

Over-Current Protection (OCP)

Under-Voltage Protection (UVP)

Short Circuit Protection (SCP)

Over - Temperature Protection (OTP)

Vout

Specification

+3.3VDC80mV

+5VDC80mV

+12V1DC150mV

+12V2DC150mV

+12V3DC150mV

+12V4DC150mV

-12VDC150mV

+5VSB

80mV

Summary of Contents for ZM750-HP

Page 1: ......

Page 2: ...ution Caution Neglecting the following may cause minor injuries degrade product conditions or cause malfunction Operating the product in an extremely cold or hot environment can degrade product performance and lifespan Liquids that enter the product may cause malfunction Operating in a humid or non ventilated environment may reduce product lifespan 2 Components To ensure a safe and easy installati...

Page 3: ...tic reduction in noise levels Improved Power Factor Reduced Harmonics through Active PFC By implementing Active PFC Power Factor Correction the Power Factor PF is improved up to 99 while harmful harmonic frequencies are reduced to meet the Line Harmonic Distortion Requirement of IEC61000 3 2 Class D High Efficiency Design and 80 PLUS Certified This power supply is capable of reaching a maximum of ...

Page 4: ...l of the plugs from ODDs HDDs Gold Plated Terminals and 16AWG Wires All connector terminals are gold plated to minimize contact resistance and power lose 16AWG thicker than 18 AWG wires are incorporated to minimize voltage drop during high load operation Sleeved Cables All power cables are sleeved for easy cable management and improved air circulation inside the computer case Multiple Safety Featu...

Page 5: ...5 Specifications Output Power Cable Specifications Cable Types and Function Using the Dual Connector ZM DC1 5V Connector 3 Pin Power Supply Peripheral Connector 12V Fan Connector ...

Page 6: ...age 100VAC 240VAC 10 Frequency 47Hz 63Hz 115VAC 12A 230VAC 5 5A Active PFC 99 Maximum 115VAC 60A 230VAC 100A 86 Max 230VAC Typical load Vout Regulation Range 3 3VDC 5 3 14V 3 47V 5VDC 5 4 75V 5 25V 12V1DC 5 11 4V 12 6V 12V2DC 5 11 4V 12 6V 12V3DC 5 11 4V 12 6V 12V4DC 5 11 4V 12 6V 12VDC 10 10 8V 13 0V 5VSB 5 4 75V 5 25V DC Output ZM750 HP Vout Output Load Rating Combined Imin Imax Ipeak Power 3 3V...

Page 7: ...ation of the Safety Precautions and the Notes on Installation in this manual B Human fatality and or property damage due to events of natural causes C External case damage electrical problems and damage to components caused by careless mishandling Disclaimer Zalman Tech Co Ltd is not responsible for any damages due to external causes including but not limited to improper use problems with electric...