background image

plik: inst_zamel_gb_GPSY | modyfikacja: 07.06.2016

plik: inst_zamel_gb_GPSY | modyfikacja: 07.06.2016

INSTALLATION

1.  Before purchase, measure the surface the heating cable will be applied to.

2.  Choose a heating cable of an appropriate length and expected heating power. The distance between successive runs of the heating cable must not be 

less than 6 cm.

3.  Make a draft of the heating cable arrangement. Specify and mark the installation place with the temperature regulator, electric supply and sensors of the 

temperature regulator. A draft or pictures are an integral part of the as-built documentation.

4.  Unpack particular elements and inspect visually of what you have received.

5.  Check the heating cable resistance with the supply cable based on the value given on the label. Write it down in the Warranty Card.

6.  Prepare the connection place of the heating cable and a temperature regulator to the electrical installation.

7.  Prepare the protection corrugated pipes for the separate insertion of: a supply cable of the heating cable and a sensor’s signalling cable.

8.  Clean the floor of sharp and dangerous items.

9.  Unfold the mounting tape type TMS-01 on the surface, where the heating cable will be arranged and attach it to the floor. The recommended distance 

between mounting clips of the heating cable should not be more than 25 cm. The radius of the heating cable bending shall not be less than 10 times of 

its diameter.

10. Place the heating cable on the previously prepared surface and grasp it by means of “inner clamps” of the mounting clip. The heating cable should be laid 

along the edges in a previously carved groove. This protects the cable from damage of the outer coating. Do not pull or stretch the wires in order to avoid 

damage of the cold „joint” connection of the supply cable with the heating cable. In order to effectively de-ice it is recommended to place the heating cable 

not  further than 3.5 cm from the outer edge of the groove. The heating cable must not be shortened.

Fig. Mounting the heating cable in the mounting clips type TMS-01

Fig. arranging of a heating cable on the stairs

11.  After the heating cable has been paid, the supply cable must be connected to the electrical installation. The supply cable must be put through a protective 

corrugated pipe.

12. Carry out the second resistance measurement of the heating cable and supply cable. Write it down the results in the Warranty Card.  

13. Place in a previously planned place the temperature regulator sensor, humidity sensor or ice and snow sensors in a protective corrugated pipe. If neces-

sary, make a groove and insert the corrugated pipe.

14. On such a floor you can spread adhesive/concrete, put tiles or another form of floor covering. The heating cable, power supply cable and protection cor-

rugated pipes should be completely covered with adhesive/concrete layer.

15. In the area of the heating cable it is forbidden to have a permanent building, to fix bolts, screws or other mounting elements that can damage the cable.

Connection of the heating cable to the electrical installation should be carried out by a qualified electrician staff with suitable authorisations. 

The installation should be in accordance with standards valid in a particular country.

The electrical installation, the GPSY heating cable is connected to with a supply cable, should be made in accordance with

applicable national regulations.

WARRANTY

WARRANTY CARD

ZAMEL Sp. z o.o. declares and assures that the electric heating systems MATEC (heating cables) manufactured and supplied by ZAMEL Sp. z o.o. are 

compliant with current standards in the Company and binding norms in Poland. The warranty includes all MATEC products under the condition of proper 

storage, transport, installation and operation according to binding norms. There is 2 year warranty for MATEC products and the warranty refers to defects 

made by the manufacturer itself.

GENERAL WARRANTY CONDITIONS AND CLAIM CONSIDERATION BY ZAMEL Sp. z o.o.

1. ZAMEL Sp. z o.o. assures warranty for MATEC products. There is 2 year warranty for the heating cables. Warranty time starts at the moment of product 

sell by ZAMEL Sp. z o.o. to the Purchaser. Be able to provide as a proof of purchase of the product an invoice by ZAMEL Sp. z o. o.

2. ZAMEL Sp. z o.o. shall process the claim at its own discretion.

3. The purchaser must inform about the claim which will be considered within 14 workdays only after proper claim notification. The PURCHASER shall lay 

any claims in writing to the Authorised Point or ZAMEL Sp. z o.o. only on presentation of an invoice (or its number and date of issue).

4. The properly filled Warranty Card should include the installation scheme or photo of the Heating Mat layout. The scheme must include:

•  Heating Mat layout with distances from walls and permanent units,

•  The position of the temperature regulator and power supply cables (with distances).

5. The claim consideration of a Purchaser is at the moment of a completely installed product. Then ZAMEL Sp. z o.o. makes inspection and necessary 

measurements in the product installation place. In case ZAMEL Sp. z o.o. is not the manufacturer of the claimed product or in case the claim is deemed 

void by ZAMEL Sp. z o.o., the Purchaser will bear all the costs connected with claim consideration.

6. When your Warranty is invoked, your damaged product will either be repaired or replaced free of charge to yourself by ZAMEL Sp. z o.o.

7. The manufacturer warranty is not valid in below cases:

•  damage caused by unauthorised modifications made by the PURCHASER or any third parties to the product

•  mechanical damage of the device

•  wrong power supply

•  electric installation which is not compliant with current IEE wiring regulations and installations

•  damage caused by incorrect product mounting - not according with MATEC Installation Manual.

8. In case of product claim by an indirect Purchaser of ZAMEL products, the Purchaser is obliged to present the claim to the Supplier (where the product was 

purchased).

CAUTION: The electrician is obliged to present and supply the user with as-built documents and a completely filled Warranty Card.

ZAMEL Sp. z o.o.

Installation place

Post code, city/town

Street, Home/Flat No

Telephone

Filled by the electrician

Electrician Name/Surname

Telephone

Nr of a Certified Electrician / 

Expire date of a Certified Electrician

Installation date

Resistance measurement results of the complete Heating Mat:

After laying the heating cable

in the pre-planned place [Ω]:

After laying the heating cable 

on the surface 

and before connecting it

to the electrical installation [Ω]:

Signature / stamp

Place for the Heating cable label

OPERATION

Operation of the heating system 

is limited to switching on the tem-

perature regulator and to adjust 

the required temperature. 

The device is designed for single-phase installation and must be installed in accordance with standards 

valid in a particular country. The device should be connected according to the details included in this op-

erating manual. Installation, connection and control should be carried out by a qualified electrician staff, 

who act in accordance with the service manual and the device functions. Before  installation make sure 

the connection cables are not under voltage. Improper transport, storage, and use of the device influence its wrong 

functioning. It is not advisable to install the device in the following cases:  if any device part is missing or the device 

is damaged or deformed. In case of  improper functioning of the device contact the producer.

The symbol means selective collecting of electrical and electronic equipment. 

It is forbidden to put the used equipment together with other waste.

UWAGA

Places

of grooves

Mounting tape TMS-01

Heating cable

Reviews: