DEVICE CONFIGURATION

SOFTWARE UPGRADE

GRM-10 has a default factory settings. Before use, carefully read the manual instruction and make a proper device configuration. In order 

to freely manage the configuration settings, the GRM-10 device makes the local and remote configuration possible. The remote configura-

tion allows to manage the settings of the already working GRM-10 device without a physical access to it (for example, to a device that is 

installed in the building). The configuration can be done as follows:

a) by means of a mobile phone via text massage (local and remote configuration),

b) by means of the PC application via the Micro USB interface (only the local configuration).

Local configuration by means of a mobile phone

1. Press the PK2 push-button on the front panel.

2. Switch on the power supply and keep the PK2 push-button pressed. 

3. Hold the PK2 push-button as long as the LED red diodes LEDP1 and LEDP2 start flashing.

4. Wait until the GRM-10 device logs into the GSM network (LED yellow diode GSM flashes).

5. Adjust the configuration parameters by sending appropriate text messages (see CONFIGURATION COMMANDS).

6. Switch off the power supply from the mains.

Remote configuration by means of a mobile phone

The remote configuration is available only for these telephone numbers that have been added to the so called administrative numbers’ list 

by means of the configuration command ADMIN (see CONFIGURATION COMMANDS) during the local configuration (by means of a text 

message or a PC application). The remote configuration is possible during a usual device operation if it is “logged in” to the GSM network.

1. Send a text message with a CONFIG MODE content from a telephone number included on the  ADMIN list.

2. By receiving the above text message, the GRM-10 device will send back a reply “CONFIG  MODE OK’ and will enter the configuration 

mode, which is indicated by flashing red LED diodes  LEDP1 and LEDP2.

3. Carry out the device configuration in accordance with the CONFIGURATION COMMANDS.

4. Send a TEXT MESSAGE with the CONFIG MODE END content to leave the remote  configuration mode.

5. By receiving the above text message, the GRM-10 device will send back a reply “CONFIG  MODE END -OK’ and will enter a usual 

operation mode

When entering / leaving the  remote configuration mode, the outputs’ status remains unchanged.

Configuration by means of the PC application via an MIC RO USB interface

NOTE: Every time before making any changes in the configuration settings by means of the PC application, first read the current configu-

ration of the GRM-10 device. It is necessary not to overwrite or lose the configuration settings implicated by the telephone text message.

1. Start the GRM-10 application on PC.

2. Switch off the power supply to connect the MICRO USB to the GRM-10 device.

3. Wait until the GRM-10 device appears in the operating system to install properly.

4. READ CURRENT GRM-10 DEVICE CONFIGURATION.

5. Carry out / change the configuration adjustments by means of the PC application.

6. In order to save the current configuration of the GRM-10 device, press the “ZAPISZ DO URZĄDZENIA” push-button.

7. Press shortly the PK1 push-button on the front panel of the GRM-10 device (LED yellow diode RS485 switches on for a moment).

8. If the configuration is correct, the application sends back a message ‘CONFIGURATION OK.’ Otherwise the message ‘CONFIGURA-

TION ERROR’ displays.

9. Disconnect the MICRO USB cable from the GRM-10 device.

Saving the configuration to *. zml file

The current configuration can be saved to a ‘*.zml’ file. In order to do it, by means of the application press the “ZAPISZ DO PLIKU’ push-

button and select the proper file place to save it.

Reading the configuration from the *. zml file

The current configuration can be read from the ‘*.zml’ file. In order to do it, by means of the application press the “WCZYTAJ Z PLIKU” 

push-button, next choose the correct file place to read it.

The GRM-10 user has the ability to upgrade the software using the Micro USB interface. It may be necessary in case of an upgrade 

release by the producer. Information on the current software can be found on the product website:

http://www.zamelcet.com/pl,263,4537,sterownik_gsm_modulowy_2kanalowy_grm10.html.

The upgrade is carried out by the GRM-10 application on 

the PC:

1. After switching off the power supply voltage connect the 

GRM-10 device to the PC by means of a USB, Micro B / 

USB cable and pressing the PK2 push-button.

2. Start the GRM-10 application and select the UPGRADE 

window.

3. Select “Software Upgrade” and then select the latest 

version of the GRM-10 software (the *. ZMS) from a 

specific location.

4. If the software is successfully updated the application 

will show a comment: “The software has been updated”.

5. Press “OK.”

6. Disconnect the USB Micro B / USB A cable.

7. Switch on the power supply.

CONNECTION AND INSTALLING DIAGRAM

CAUTION!  The  GRM-10  controller  connection  to  a 

single-phase  installation  must  be  done  in  accord-

ance with standards valid in a particular country. The 

device should be connected according to the details 

included in this operating manual. Installation, con-

nection and control should be carried out by a quali-

fied electrician staff, who act in accordance with the 

service manual and the device functions.

1. Disconnect power supply by the phase fuse, the cir-

cuit-breaker or the switch-disconnector combined to 

the proper circuit.

2. Check if there is no voltage on connection cables by 

means of a special measure equipment.

3. Connect the GRM-10 device to 230 V AC power sup-

ply.

4. Connect the remaining cables with the appropriate 

terminals of the GRM-10 controller according to the 

installing diagram.

5. 

Insert into the SIM input the active SIM card with 

funds  available.  Before  installing  switch  off  the 

PIN code or adjust it choosing 1111. It is recom-

mended to switch off the voice mail.

6. Carry out a proper device configuration (see DEVICE 

CONFIGURATION).

7. Switch on the power supply from the mains. Wait until 

the proper GSM network log in. Check the correctness 

of the operation.

Optional element

to control

EXTA FREE

receivers

Summary of Contents for GRM-10

Page 1: ...puts with a maximum load capacity of 16 A 250 V AC Two digital inputs allow for a link with the alarm control panels The RS485 in terface in connection with the RXM 01 translator gives a possibility t...

Page 2: ...he GRM 10 application on the PC 1 After switching off the power supply voltage connect the GRM 10 device to the PC by means of a USB Micro B USB cable and pressing the PK2 push button 2 Start the GRM...

Page 3: ...pes Remarks MANUAL By means of PK1 PK2 push buttons on the front panel Bistable ON OFF Time TIME Gate GATE Times for TIME and GATE modes are adjusted during con figuration CLIP By calling to the devic...

Page 4: ...essively entered phone numbers preceded by 48 The text messages will be sent to these numbers The confirma tions refer to the changed output status and occurences on IN1 IN2 inputs The maximum of numb...

Page 5: ...ng a text message MESSAGE with a defined content X number of an input output 1 input output IN1 OUT1 2 input output IN2 OUT2 tx f the output must be active for a period of time TIME then the parameter...

Page 6: ...s is 0x01 The address is important for a larger number of RXM 01 operating independently on a single object 3 Following the description of the PC add programme particular push but tons sent by the RXM...

Page 7: ...X ON Electronics Authorized Distributor Click to view similar products for LED Lighting Fixture Accessories category RZB03 ASM10 ORDBYE115 STR21230V AS223 ORAE1336G ORAE1373 ORWE501 ORWE504 ORWE514...

Reviews: