VER. 001_03.11.2009
MOUNTING, FUNCTIONING
1. Disconnect the power supply from the
mains by the phase fuse, the circuit-
breaker or the switch-disconnector
that are joined to the proper circuit,
2. Check if there is no voltage on con-
nection cables by means of a spe-
cial measure equipment,
3. Install PBM-01 device in the switch-
board on TH-35 DIN rail,
4. Connect the cables with the terminals
according to installing diagram,
5. Switch on the power supply from the
mains,
6. Push the TEST button several times
to check the relay operation correct-
ness.
The device is ready to work after
switching on power supply. The relay
operation correctness can be checked
by pushing the TEST button placed
on the front panel. The system should
switch on and off the load connected to
its output terminals. Mono modular pu-
shbuttons can be connected in a paralell
way which enables the lighting control
from different places. Lighted pushbut-
tons version is possible.
APPLICATION
CONNECTION
DIMENSIONS
PRODUCT FAMILY
Typical use:
The bistable relay operating the stair-
case lighting (e.g. indoor lighting) are con-
trolled by means of mono modular push-
buttons that can be connected in a parallel
way. The buttons can be placed in different places which gives the possibility of creating universal
lighting systems control. The bistable relay cooperates with time relay PCM-04 (with set-ups:
MODE=F, TIME=3, RANGE=2) and the same gives additional function of the central bistable
relay switch off (reset) by momentary power cut.
Signal separator coordination SEM-01:
In the bistable control systems signal separators can be used to divide control signals into
particular relay groups.
WARRANTY CARD
There is 24 months guarantee on the product
Salesman stamp and signature, date of sale
1. ZMIE ZAMEL SP. J. assures 24 months guarantee for the product.
2. The manufacturer’s guarantee does not cover any of the following actions:
a) mechanical damage during transport, loading / unloading or under other circumstances,
b) damage caused by incorrect product mounting or misuse,
c) damage caused by unauthorised modi
fi
cations made by the PURCHASER or any third parties to the product or any other devices
needed for the product functioning,
d) damage caused by Act of God or any other incidents independent of the manufacturer.
3. The PURCHASER shall lay any claims in writing to the dealer or ZMIE ZAMEL SP. J.
4. ZMIE ZAMEL SP. J. is liable for processing any claim according to current Polish legislation.
5. ZMIE ZAMEL SP. J. shall process the claim at its own discretion: product repair, replacement or money return.
6. The manufacturer’s guarantee is valid in the Republic of Poland.
7. The PURCHASER’s statutory rights in any applicable legislation whether against the retailer arising from the purchase contract or
otherwise are not affected by this warranty.
TIME COURSE
RELAY CAPACITY
INNER DIAGRAM
The time relay PBM-01 belongs to PBM
time relay product family.
t
IN
t
t
U
L
N
T
11
14
11
IN
IN
IN
Supply version:
24V - 24V AC/DC
available for
PBM-01, PBM-02, PBM-03,
12-24V- 12÷24V AC/DC
available for
PBM-05
U -
universal supplying voltage
12÷230V AC/DC
Device version:
01 - basic
02 - extended:
SET
,
RESET
functions
and state storage
03 - with time limit function
04 - zero current consumption with
time limit function
05 - zero current consumption,
SET
,
RESET
functions and time limit
function
Casing type:
M - modular version (TH 35 DIN rail)
P -
fl
ush junction box Ø60 version
Device type
CENTRAL RESET
BISTABLE RELAYS
LOCAL
CONTROL