230 V AC

14 V DC

750 W 

250 W 

500 W 

375 W

CAUTION ! The device is designed for single-phase installation and must be installed 

in accordance with standards valid in a particular country. Installation, connection 

and control should be carried out by a qualified electrician staff, who act in accord-

ance with the service manual and the device functions.
1.  Disconnect power supply by the phase fuse, the circuit-breaker  or the switch- discon-

nector combined to the proper circuit.

2. Check if there is no voltage on connection cables by means of a special measure equip-

ment.

3. Connect the power supply to 230 V AC.

4. 4. Connect the output cables with appropriate receiver’s cables in accordance with the 

connection diagram.

5. Mount the controller in the Ø60 junction box.

6. Switch on the power supply from the mains.

7. Add selected transmitters to the receiver (description in the  TRANSMITTERS’ PRO-

GRAMMING section) and check if they work properly.

ROP-03 receiver is designed to carry out simple control functions in the low-voltage instal-

lations from 10 ÷ 14 V DC. This device in connection with any wireless EXTA FREE  (www.

extafree.pl)system transmitter enables the realisation of the switch on / switch off func-

tion, the monostable mode, the bistable and time modes. The receiver is recommended 

for use with LED diode lighting. ROP-03 device has two potential free (NO) relay outputs 

with a maximum capacity of 5 A for 250 V AC. Small dimensions of the casing allow for 

a direct mounting of the receiver in the Ø60 mm junction box. The product belongs to 

the ECOLINE group and is characterised by low power consumption. The features of the 

controller:

• cooperation with wireless EXTA FREE system transmitters,

• realisation of the control function in low voltage installations including LED diode lighting,

• two output relays (dry contacts),

• the possibility of independent control of two circuits,

• multiplicity of operation modes: switch on / switch off, monostable, bistable, time,

• wide operation range (up to 230 m outdoors),

• a possibility to increase the operation range by using RTN-01 retransmitter,

• operation is optically signalled,

• low power consumption in the standby mode (0.15 W) - a device designed for continu-

ous operation.

TECHNICAL DATA

MOUNTING

DESCRIPTION

DIAGRAM

APPEARANCE

Nominal supply voltage:

10 ÷ 14 V DC

Nominal power consumption:

0,7 W

Number of channels:

2

Maximum current in the channel:

5 A / 250 V AC

Relay contacts parameters:

2xNO 5 A/250 V AC1 1250 VA

Modes:

Switch on/switch off, Monostable, Bistable, Time

Control:

EXTA FREE system transmitters

Radio transmission:

868,32 MHz

Transmission method:

One-way without confirmation

Coding:

Yes – transmission with addressing

Maximum number of transmitters:

32

Range:

Up to 230 m in the open area

Time adjustment:

1 s ÷ 18 h

Ambient temperature range:

 -10 ÷ +55 

o

C

Mounting:

In a Ø60 junction box

Casing protection degree:

IP20

Protection class:

III

Dimensions:

47,5 x 47,5 x 20 mm

Weight:

36 g

Reference standard:

PN-EN 60669; PN-EN 60950; PN-EN 61000

Channel 1 terminals (12, 11 )

Channel 2 terminals (22, 21)

Power supply terminals (+, -)

Optic signalling of the 

receiver’s operation

Programming button

MAXIMUM CURRENT CAPACITY:

ZNP, ZNN or ZNM series 

of the power supply

in 14 V DC version

Exemplary LEDIX

series fittings

Summary of Contents for ROP-03

Page 1: ...on the monostable mode the bistable and time modes The receiver is recommended for use with LED diode lighting Characteristic features cooperation with wireless EXTA FREE system transmitters independent control of up to two receivers in the following modes switch on switch off monostable bistable time 2 relay potential free outputs NO with a maximum capacity of 5 A for 250V AC wide operation range...

Page 2: ...on box The product belongs to the ECOLINE group and is characterised by low power consumption The features of the controller cooperation with wireless EXTA FREE system transmitters realisation of the control function in low voltage installations including LED diode lighting two output relays dry contacts the possibility of independent control of two circuits multiplicity of operation modes switch ...

Page 3: ... switches on first signal pulsates next the signal is constant Wait for the third time about 5 seconds until LED red diode switches on first signal pulsates next the signal is constant After the adjusted time is finished the number of LED red diode flashes press PROG push button and then release it TIME IS ADDED After the adjusted time is finished the number of LED red diode flashes press PROG pus...

Page 4: ...t signal Next release PROG push button Press PROG push button of ROP 03 device for a longer time until LED red diode switches on constant signal Next release PROG push button Press the transmitter s push button for a longer time Release the transmitter s push button LED red diode switches on first the signal pulsates next the signal is constant Press the same transmit ter s push button and release...

Reviews: