background image

DESCRIPTION

FEATURES

• control of window roller blinds or other devices by means of single-phase 230 V AC motors,

• compatible with a controller and EXTA LIFE system transmitters,

• two-way transmission – current roller blind position indicated in the application (% of c 

icon),

• maximum load: 350 W (2 A) - class AC-3,

• programmable external inputs (local and central control functions),

• connection possibility of a single or double roller blind push-button,

• programmable roller blind movement time,

• 2 programmable “favourite” settings for transmitters and external inputs,

• maximum 4 programmable „favourite” settings selected by means of an application,

• 2 operation modes in cooperation with transmitters (local / central),

• control type selection by means of an application: open – stop – close + roller blind position 

change by means of a slider,

• software update possibility,

• mounting in Ø60 mm junction box.

Flush roller blind controller SRP-22 is designed to control window roller blinds or other devices 

driven by 230 V AC one-phase motors. The control can be carried out either wired, by means of 

transmitters or the EXTA LIFE controller or wireless by means of debouncing roller blind push but-

tons. IN1 and IN2 inputs, configured in a mobile application, are used in the wired type of control. 

The inputs can operate in a local or central control mode. Single and double roller blind push-

buttons can be applied in both cases. Due to the two-way communication between a receiver and a 

controller, the current roller blind mode is shown in the mobile application by means of a respective 

icon and a “closing position” parameter.  This two-way communication allows for parameterisation 

of the controller and a remote adding of transmitters (without a physical access to a receiver). Frame 

encoding algorithm ensures control security, which is particularly important in case of roller blinds 

and garage gates.  SRP-22, apart from the controller, can be simultaneously operated by EXTA 

LIFE system transmitters. A larger number of transmitters can be added to a receiver which, in turns, 

enables an independent control from several places. The device is designed for (surface and flush) 

junction box installation. The receiver has an implemented function of a remote software update by 

means of the controller. The controller’s functionality has been increased by the following functions: 

programmable roller blind movement time and a possibility to define up to four favourite settings.

APPEARANCE

IN1 – roller blind push-button 

terminal (default setting: 

downward movement)
IN2 – roller blind push-button 

terminal (default setting: 

upward movement)
Motor terminals 

(downward movement)
Motor terminals 

(upward movement)
Power supply terminals L, N

Signalling diode - RGB

(receiving / transmission / mode)

Programming push-button

Summary of Contents for SRP-22

Page 1: ...operate in a local or central control mode Single and double roller blind push buttons can be applied in both cases Due to the two way communication between a receiver and a controller the current rol...

Page 2: ...special measuring equip ment 3 Connect the device cables with the terminals in accordance with the installing diagram 4 Install SRP 22 in a junction box 5 Switch on the power supply from the mains and...

Page 3: ...means of the mobile application 10 A remote software update of a controller is also possible due to the mobile application the EXTA LIFE controller must be connected to the Internet 3 It is recommende...

Page 4: ...a roller blind in a desired position The central mode is used mainly to control a group of roller blinds or to cooperate with sensors In this mode pressing shortly one push button realises the opening...

Page 5: ...blind closure A single push button can activate only one favourite setting programmed as setting 1 Central control In this mode pressing shortly 0 5 sec a roller blind push button the SRP 22 activates...

Page 6: ...perate properly by means of the mobile application The of roller blind closure is calculated on the basis of these times Favourite position positions By means of a mobile application it is possible to...

Page 7: ...means of the EXTA LIFE mobile application DIRECT PROGRAMMING BY MEANS OF PROG PUSH BUTTON To assign radio transmitters directly to a receiver use the receiver s PROG push button ASSIGNING PUSH BUTTON...

Page 8: ...ed 1 Pair the selected SRP 22 receiver with a controller 2 Pair the controller with a transmitter whose buttons you want to assign remotely to a receiver 3 Choose the Assign a receiver option by means...

Page 9: ...ckly to signal times have been assigned correctly PROGRAMMING ROLLER BLIND MOTION TIME In the SRP 22 controller the default closing and opening time of a roller blind is adjusted to 120 seconds During...

Page 10: ...m pletely 2 After a complete roller blind opening press again the Configure closing time push button it causes the roller blind closes 3 Immediately after a complete roller blind closure press again t...

Page 11: ...ly 2 Press the PROG push button shortly 1sec in a receiver STATUS LED switches on blue 3 Wait for about 5 seconds till STATUS LED switches on red 4 Wait another 5 seconds till STATUS LED switches off...

Page 12: ...utton and in 5 sec press it again shortly 3 The STATUS LED flashes orange to signal the deleting is ongoing The LED flashes orange quickly to signal the operation has been completed successfully FAVOU...

Page 13: ...E DELETION OF TRANSMITTERS BY MEANS OF EXTA LIFE APLICATION In case we want to delete remotely push buttons of a transmitter from a receiver it is required that the receiver is paired with the EXTA LI...

Page 14: ...moves up or down By marking fields next to the TEST push button we choose receivers to be paired with the EXTA LIFE controller It is possible to mark more than one receiver 4 Press the PAIR push butto...

Page 15: ...cess of receivers To protect correctly your system the following steps must be carried out 1 If there is no controller in the EXTA LIFE system switch off pairing Broadcast OFF in all receiv ers 2 If t...

Page 16: ...ol IN1 input functionality roller blind closing IN2 input functionality roller blind opening IN1 IN2 inputs are triggered only from the L line The basic functionality requires giving short 0 5 sec imp...

Reviews: