background image

User Information

Safety Emergency Stop Relay SR3D 

E10-2 

Ver. B 

E61-139-00 

• 

2 start performances: 

  -  monitored manual start 

  -  automatic start 

• 

Short-circuit monitoring and earth fault monitoring 

• 

Up to PL e, SILCL 3, category 4 

Correct Use 

SR3D is an all-purpose emergency stop device which ensures the 

quick and safe deactivation of the moving parts of a machine in 

case of danger.  

Applications for the SR3D include single or dual-channel emer-

gency  stop  circuits  and  guard  monitoring  on  machines  and 

plants. 
The  SR3D  is  specially  designed  and  certified  for  the  use  in 

furnaces and ancillary equipment in continuously mode accord-

ing  to  EN  50156-1  and  the  use  on  ships,  cetified  by  Ger-

manischer Llloyd. 

Features 

• 

3 safety contacts 
1 auxiliary contact 

• 

Connection of: 

• 

    -  Emergency stop buttons 
    -  Safety switches 
    -  Non-contact safety switches 
    -  OSSD-Outputs 

• 

Control: single or dual channel 

• 

Feedback loop for external contactors or extension    
modules    

• 

Redundancy and cyclical monitoring 

• 

Diversified forcibly guided output relays 

• 

LED indicator for status channel 1 and 2 

Function  

The  emergency  stop  safety  switching  device  SR3D  is 
designed  for  safe  isolation  of  safety  circuits  according  to 
EN 60204-1 and can be used up to safety category 4, PL e 
according to EN ISO 13849-1. 

The  internal  logical  system  closes  the  safety  contacts 
when the start button is pressed. 

If  the  safety  switch  is  opened,  the  positively  driven  safety 
contacts  are  opened  and  safely  switch  the  machine  off.  It 
is ensured that a single fault does not lead to a loss of the 
safety  function  and  that  every  fault  is  detected  by  cyclical 
self-monitoring  no  later  than  when  the  system  is  switched 
off and switched on again. 

Electrical 
Connection 

• 

When the 24 V version is used, a safety transformer 
according to EN 61558-2-6 or a power supply unit with 
electrical isolation from the mains must be connected. 

• 

External fusing of the safety contacts (6 A slow-blow or 
8 A quick-action or 10 A gG) must be provided. 

• 

A maximum length of the control lines of 1000 meters 
with a line cross section of 0.75 mm

2

 must not be ex-

ceeded. 

• 

The line cross section must not exceed 2.5 mm

2

• 

If the device does not function after commissioning, it 
must be returned to the manufacturer unopened. Ope-
ning the device will void the warranty. 

Installation 

As  per  EN  60204-1,  the  device  is  intended  for  installation 
in control cabinets with a minimum degree of protection of 
IP54.  It  is  mounted  on  a  35  mm  DIN  rail  according  to                
DIN EN 60715 TH35. 

For  the  AC  115V/230V  type,  keep  a  minimum  space  of 
10mm between the devices. 

Safety 
Precautions 

Fig. 1 Block diagram SR3D 

Safety Emergency Stop Relay SR3D 

German Lloyd 

Certificate 32915-06HH 

Fig. 2  Mounting / Demounting 

Fig. 3  Terminals 

A1:  

Power supply 

A2 : 

Power supply 

S11:  

DC 24 V control voltage 

S10:  

Control line 

S21: 

Start control line 

S13: 

Control line 

S14: 

Control line 

S12: 

Control line 

13-14: 

Safety contact 1 

23-24: 

Safety contact 2 

33-34: 

Safety contact 3 

English translation 

• 

All relevant safety regulations and standards are to be 
observed. 

• 

The overall concept of the control system in which the 
device is incorporated must be validated by the user. 

• 

Failure to observe the safety regulations can result in 
death, serious injury and serious damage. 

• 

Note down the version of the product (see label “Ver.”) 
and check it prior to every commissioning of a new de-
vice. If the version has changed, the overall concept of 
the control system in which the device is incorporated 
must be validated again by the user. 

• 

Installation and commissioning of the device must be 
performed only by authorized personnel

• 

Observe the country-specific regulations when installing 
the device. 

• 

The electrical connection of the device is only allowed to 
be made with the device isolated. 

• 

The wiring of the device must comply with the instruc-
tions in this user information, otherwise there is a risk 
that the safety function will be lost. 

• 

It is not allowed to open the device, tamper with the 
device or bypass the safety devices. 

Microlectra bv.

Hermanus Boerhaavestraat 6.   3261 ME Oud-Beijerland.  Netherlands.

Tel 31(0)186-616290      Fax 31(0)186-610349            www.microlectra.nl      info@microlectra.nl

Reviews: