Quick Start Guide ZX-FPGA-PLC 

Power supply 

Connect the device according to the illustration.

 

Terminal 

Description 

L+

 

Positive supply voltage U

B

 

M (2 equivalent terminals)

 

0 V 

-

 Connection of the supply voltage and the voltage for the dig. Out-

puts  and  0  V 

-

  potential  for  digital  inputs.  M  and  0  V  are  internally 

connected with each other

 

U+

 

Positive  voltage  for  the  dig.  Outputs  (may  be  different  from  operating 

voltage L+)

 

Digital Input           01, 02, ... 

 

Digital inputs

 

Digital Output        01, 02, ...

 

Digital inputs

 

Analog Input        A

1

+ /

 

0 V, A

2

+ /0 V, ...    

Analog voltage or current inputs (ZX21TPA and ZX21TCA only)

 

Analog Output     A

1

+ /

 

0 V, A

2

+ /0 V, ...    

Analog voltage outputs (ZX21TPA and ZX21TCA only)

 

       

 

Ethernet port

 

SSI/TTL

 

SSI  or  ZanderLink  interface  or  TTL  differential  inputs  or  outputs 

(ZX21TPA  and  ZX21TCA  only).  The  interface  can  be  used  in  the  user 

program  for  ZanderLink,  SSI  encoders  or  as  inputs  or  outputs  for 

 

(LV)TTL  differential  signals  (e.g.  for  connecting  a  suitable  incremental 

encoder).

 

PROFINET IO

-

Device                                  

 

PROFINET interface (ZX21TP and ZX21TPA only)

 

EtherCAT Slave

 

EtherCAT interface (ZX21TC and ZX21TCA only)

 

ZX20T, ZX21TP/TC 

108

ZX20T

 

ZX21TP/TC

 

BF / ERR

 

SF / RUN

 

SYS

 

Digital Input

 

01  02  03  04  05  06 07  08  09  10 

11  12  13  14  15  16 17  18  19 20 

U

Power

 

L M

 

M

 

Digital Output

 

01  02  03  04  05  06 

07  08  09  10  11  12  13  14  15  16 

PROFINET IO

-

Device

 

EtherCAT Slave

 

RX/TX

 

RX/TX

 

Link

 

Link

 

IN

 

OUT

 

L/A

 

L/A

 

Pwr

 

Digital Output

 

   Digital Input 

ZX21TPA/TCA 

ZX21TP/TC

 

The  controllers  of  the  ZX21  family  (ZX21TP,  ZX21TC, 

ZX21TPA, ZX21TCA) are delivered including plug

-

in termi-

nals with lateral cable outlets (see picture).

 

 
 
 
 
 
 

Plug-in terminal with lateral cable outlets 

The  controllers  of  the  ZX09  and  ZX20  family  (ZX09, 

ZX09A, ZX09D, ZX09E and ZX20T) are delivered including 

plug

-

in  terminals  with  upper  cable  outlets  (see  picture). 

Terminal  sets  with  lateral  cable  outlets  are  available  as 

accessories (see next page, "Accessories").

 

 
 
 
 
 
 

Plug-in terminal with upper cable outlets 

Plug-in terminals 

Connect the device to the supply voltage  according  to  the 

illustration.

 

Warning:  

Do not connect terminal M with PE of the power supply, as 

this  can  lead  to  massive  EMC  interference.  For  shielded 

lines  (e.g. lines for  analog signals or  RS

-

485 lines),  use a 

shield rail to connect the shield to PE with low resistance.

 

Connection of the power supply 

U+

 

       Power 

L+

 

M

 

M

 

24 V 

0 V 

 

Summary of Contents for ZX09 Series

Page 1: ...IOut 250 mA 500 kHz 35 100 ZX21TP DC 24 V 15 20 ns 3584 7168 9 s bei IOut 250 mA 500 kHz 50 200 ZX21TC DC 24 V 15 20 ns 3584 7168 9 s bei IOut 250 mA 500 kHz 50 200 ZX21TPA DC 24 V 15 20 ns 3584 7168...

Page 2: ...es muss den Anweisungen dieser Betriebsanleitung entsprechen Das ffnen des Ger tes und jegliche Manipulationen am Ger t sind unzul ssig und f hren zum Verlust von Garantie oder Gew hrleistungsanspr ch...

Page 3: ...ung f r die digitalen Ausg nge sowie 0 V Potential f r digitale und analoge Ein g nge M und 0 V sind intern miteinander verbunden U Anschluss f r die positive Spannung die von den digitalen Ausg ngen...

Page 4: ...ttstelle ZanderLink oder TTL Differenz Ein Ausg nge nur ZX21TPA und ZX21TCA Die Schnittstelle ist im Anwenderprogramm nutzbar f r ZanderLink SSI Drehgeber oder als Eing nge oder Ausg n ge f r LV TTL D...

Page 5: ...ergreifen sind m ssen daf r zugelassene Sicherheitskomponenten wie Not Halt Einrichtungen oder Schutzt r berwachungen vorgesehen werden die das sichere Abschalten der entsprechenden Antriebe unabh ng...

Page 6: ...500 kHz 70 300 ZX09A DC 24 V 15 20 ns 9112 18224 3 s 70 s 500 kHz 70 300 ZX09D DC 24 V 15 20 ns 9112 18224 3 s 10 s 500 kHz 70 300 ZX09E DC 24 V 15 20 ns 9112 18224 3 s 10 s 500 kHz 70 300 ZX20T DC 24...

Page 7: ...cal connection of the device may only be carried out when it is de energized This also applies to the connected sensors and actuators The wiring of the device must comply with the instructions in this...

Page 8: ...the positive voltage switched by the digital outputs may be different from operating voltage L Digital Input 01 02 Digital inputs Digital Output 01 02 Digital outputs Analog Input A 0 V A1 0 V A2 0 V...

Page 9: ...nnecting a suitable incremental encoder PROFINET IO Device PROFINET interface ZX21TP and ZX21TPA only EtherCAT Slave EtherCAT interface ZX21TC and ZX21TCA only ZX20T ZX21TP TC 108 ZX20T ZX21TP TC BF E...

Page 10: ...ry Directive If additional measures are to be taken with regard to functional safety approved safety compo nents such as emergency stop devices or safety door monitors must be provided which enable th...

Reviews: