Installation
9
9. Preparations
» Flush the water line thoroughly.
Water installation
A safety valve is not required.
Taps
» Use suitable taps (see chapter „Appliance descripti-
on / Accessories“).
Note
Fitting the special aerator supplied provides an op-
timum water jet.
10. Installation
10.1 Installation site
Install the appliance in a room free from the risk of frost
and near the draw-off tap.
Ensure that the lateral fixing screws for the cover are al-
ways accessible.
The appliance is suitable for undersink installation (water
connections at the top) and oversink installation (water
connections at the bottom).
DANGER Electrocution
Protection rating IP25 is only ensured if the applian-
ce back panel is fitted.
» Always fit the appliance back panel.
10.2 Installation options
10.2.1 Undersink installation, non-pressurised, with
non-pressurised tap
26
_0
2_0
5_00
35
Appliance installation
» Mount the appliance on the wall.
Note
The wall must have a sufficient load-bearing capa
-
city.