19
Mod. CINEA CANALIZÁVEL
rev 00
Instructions for use
translated from the original text
IT
IT
FR
FR
ES
ES
NL
NL
EN
EN
• To prevent misunderstandings and unwant-
ed start-up or switch-
off
, activate only one
program at a time if you are not sure of what
you want to obtain.
• Deactivate the daily program if you want to use the
weekly program.
• Always keep the weekend program deactivated when
using weekly programs 1, 2, 3 and 4.
• Activate the weekend program only upon deactivat-
ing the weekly one.
4.7
LANGUAGE SELECTION
This allows you to select the dialogue language among those
available. To modify the language, go to the menu
04 - Choose
language
, using the keys
(1)
and
(2)
fig. 14a to scroll the items
until you reach the desired language.
fig. 21 control panel - language selection
4.8
STANDBY MODE
Activates the "STANDBY" mode which switches off the stove
after the room temperature has remained higher than the
set value beyond the default time. When the stove switches
off in this condition, it can only switch back on when the set
temperature is lower than the room temperature for a deter-
mined amount of time. To modify the mode, go to the menu
05- Standby mode,
and use the keys
(1)
and
(2)
fig. 14a to
activate it/deactivate it.
4.9
BUZZER MODE
When set at “OFF” the acoustic signal is disabled. To modify
the mode, go to the menu
06 - Buzzer,
and use the keys
(1)
and
(2)
fig. 14a to activate it/deactivate it.
4.10 INITIAL LOAD
Perform the operation below when the pellet
loading pipe is empty.
This allows you to perform a pellet preload lasting 90” with
the stove off and cold. Start by pressing the key
(1)
and inter-
rupt by pressing the key
(4)
. The following also appear on the
display: Timer
(A)
, Power
(B)
, Room Temp.
(C).
fig. 22 control panel - initial pellet loading
4.11 STOVE STATUS
Displays the instantaneous status of the stove by showing the
1
A
C
B
status of the various devices connected to it. Various pages
are available and displayed in sequence. The following also
appear on the display: Timer 1
(A)
, Time-out
(B)
, Status
(C)
,
Alarm delay
(D)
, Operating status
(E)
, Flue gas Temp.
(F)
, Flue
gas Extraction speed
(G)
, Heat exchangers 2 and 3 status
(H)
,
Instantaneous power
(I)
, Heat exchanger 2 speed
(L)
, Heat ex-
changer 3 speed
(M)
, Alarm in progress
(N)
.
fig. 23 control panel - stove status display
4.12 IGNITION
To switch the product on, press the key (1) for a few seconds.
The display shows when the snow has started (see fig. 24)
fig. 24 control panel - ignition
4.13 START-UP PHASE
The product performs the start-up phases in sequence as de-
fined by the parameters managing levels and times.
4.14 FAILED IGNITION
When a time preset by the manufacturer has elapsed and the
flue gas temperature has not reached the minimum value,
also preset by the manufacturer, the product goes into alarm
status (see table 7 problems/causes/remedies in chap. 7.3).
4.15 STANDARD OPERATION
Upon successfully completing the start-up phase, the stove
switches to the "operating" mode that represents standard op-
eration. If the flue gas temperature exceeds a value preset by
the manufacturer, the heat exchangers are enabled, fig. 25.
Heat exchangers 2 and 3 are only activated if they are en-
abled.
A
B
E
D
C
F
G
H
I
L
M
N
1