• It is forbidden to operate the product with the door
open or the glass broken.
• Do not stay a long time in front of the product while run-
ning. Do not overheat the room where
you stay or where
the product is installed. This could harm your physical con-
ditions and cause health issues.
• The product must be stored in humidity-free rooms and
not exposed to weather conditions.
• Do not remove the feet for setting the product body on
the floor to guarantee proper insulation, especially for
floors made of flammable materials.
• Place a floor protection plate as a base for the product if
the floor is made of flammable material, such as parquet
or carpets. (considering that the plate must extend be-
yond the front of the boiler by at least 25/30cm).
• It is strictly forbidden to use flammable liquids to light
the fire; the pellets light automatically when the boiler
is on.
• Extraordinary maintenance operations must only be car-
ried out by authorised and qualified personnel.
• For seasonal use of the boiler, in case of improper draught
or adverse weather conditions (temperatures < 0°C), make
sure that the chimney flue is perfectly insulated and not
obstructed to avoid freezing and any backflow of flue gas.
• If the flue catches fire, immediately switch off the product
,
unplug it and never open the door. Then call the compe-
tent authorities.
• As the product has an air consumption necessary for com-
bustion, it is recommended to connect the product to the
outside by means of suitable piping reaching the specific
inlet at the back of the boiler.
• For safety purposes, it is recommended to maintain at least
20 cm between the hot sides of the boiler and any flam-
mable cover materials (e.g. matchboarding walls, wallpa-
per etc.) or to use specific insulating materials available on
the market. This assessment must also be made regarding
furniture, armchairs, curtains and similar objects.
• To facilitate technical support interventions, do not recess
the product in tight spaces, do not push it against the wall
as this could jeopardize correct ventilation.
• The absence of draught by the flue (or, for example, the
obstruction or closing of the brazier air inlet or of the
brazier itself) alters the operation of the boiler which,
during the automatic ignition phase, could cause too
many pellets to be dispensed into the brazier due to
delayed ignition of the fire.
• The pellets feeding the product must have the characteris-
tics described in this manual.
• Do not leave children alone near the boiler while it is lit, as
all the hot parts could cause serious burns.
• Do not carry out any operation on the boiler other than
those indicated for its regular use or those recommended
in this manual to solve simple problems. Always unplug
the appliance before intervening and only operate with
the boiler cold.
• IT IS absolutely prohibited to remove the pellet tank pro-
tective grid.
• Always check and make sure that the door of the combus-
tion chamber is hermetically closed during ignition and
operation of the boiler.
• Automatic ignition of the pellets is the most delicate
phase. It is recommended to always keep the product and
brazier clean so that it can be done without any problems.
• In the presence of operating faults, the product can only
be switched back on after having solved the cause of the
problem.
• ZANTIA Climatização is not liable for inconvenience, tam-
pering with, damage, or whatsoever due to failure to com-
ply with the provisions provided in this manual.
• This booklet is an integral part of the appliance; therefore,
it must be stored and accompany the device in case of
transfer of property.
• This appliance is not intended for use by persons (includ-
ing children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concern-
ing use of the appliance by a person responsible for their
safety.
• Only use the fuel recommended by the manufacturer.
The
product cannot be used as an incinerator.
It is strictly
forbidden to use liquid fuels.
• To correctly use the product and the electronic equipment
connected to it and to prevent accidents, always observe
the indications provided in this manual.
• Before starting any operation, the user or whoever is op-
erating the product must have fully read and understood
this installation and use manual. Errors or improper set-
tings can cause dangerous conditions and/or irregular
operation.
• Switch the product off in case of failures or malfunction-
ing.
• The buildup of unburned pellets in the burner after
each "failed ignition and alarm" must be removed
before attempting another ignition. Check that the
burner is clean and well positioned before switching
it back on.
• Do not wash the product with water. Water could infiltrate
into the unit and damage the electric insulations, causing
electrical shocks.
• Install the product in rooms which are not fire hazards and
are set up with all services such as supplies (air and elec-
tric) and flue gas exhausts.
• Do not stand on the product or use it as a support struc-
ture.
• Do not dry sheets on the product. Drying racks or similar
products must be kept a safety distance from the product.
There is the risk of fire!
• All responsibility for the improper use of the product is
fully borne by the user and releases the manufacturer
from all civil and criminal liability.
• In case of failure to the ignition system, do not force igni-
tion by using flammable materials.
1.5
WARRANTY TERMS AND CONDITIONS
1. The Manufacturing Company guarantees the structure
and materials making up the product for a period of
24
months
from the date of purchase, as long as the
pur-
chaser sends the attached sheet within 8 days of the
date of delivery
, completely filled out and keeps a copy
as a proof of purchase. This warranty is valid as long as:
a) The purchaser has installed the product in compliance
with standards in force,