25
CONVERSION OF GAS
Your cooker is designed to work with natural gas,
and is convertible for use with propane or butane.
The LPG conversion kit is available from your
Service Force Centre and must be fitted by a
Corgi Registered engineer.
For changing the gas type it is necessary to:
•
replace the nozzles (hob, oven and grill);
•
adjust the minimum level (hob and oven);
•
check the gas connection;
Stick the label supplied with the
appliance (in the nozzles bag) corresponding
to the gas type utilised.
SPECIFICATION NOZZLES
Table no.1
(Cat : II
2H3+
)
Cons
Burner
Normal
power
(kW)
Simmer
power
(kW)
By-
pass
(mm)
Gas Type
Pressure
(mbar)
Nozzle
diameter
(mm)
m
3
/h g/h
RAPID 3,00
0,72
0,42
Natural Gas
Butane
Propane
20
28-30
37
1.19
0,88
0,88
0,267
-
-
-
218,1
214,2
SEMI-
RAPID
2,00 0,43 0,32
Natural Gas
Butane
Propane
20
28-30
37
0.96
0,71
0,71
0,190
-
-
-
145,4
142,8
AUXILIARY 1,00 0,35 0,29
Natural Gas
Butane
Propane
20
28-30
37
0.70
0,50
0,50
0,095
-
-
-
72,7
71,4
OVEN 3,00
1,10
0,46
Natural Gas
Butane
Propane
20
28-30
37
1.16
0,82
0,82
0,267
-
-
-
218,1
214,2
GRILL 2,00
- -
Natural Gas
Butane
Propane
20
28-30
37
0,96
0,71
0,71
0,190
-
-
-
145,4
142,8