33
Electrical connections
Any electrical work required to install this hob
should be carried out by a qualified electrician or
competent person, in accordance with the current
regulations.
THIS COOKER MUST BE EARTHED.
The manufacturer declines any liability should
these safety measures not be observed.
This cooker is designed to be connected to a
230 V 50 Hz AC electrical supply.
Before switching on, make sure the electricity supply
voltage is the same as that indicated on the hob rating
plate. The rating plate is located on the front external
edge of the oven cavity.
The cooker is supplied without supply cord. A 3 core
flexible supply cord must be fitted, in accordance with
the specification given in the relevant tables.
1) Loosen the two fixing screws securing the back
protective screen of the cooker, then lift it up
and remove it. This will expose the terminal
block on the right bottom corner.
2) Loosen the two cable clamp screws and lift
the top section of the clamp enough to allow
the cable to be passed through.
3) Connect the red (live) wire to the terminal which
is marked with the letter "L".
4) Connect the black (neutral) wire to the terminal
which is marked with the letter "N".
5) After fitting a green or yellow/green sleeve over
the bare copper wire (earth wire), connect the
exposed end to the terminal which is marked
with the earth symbol
or with the letter
"E"coloured green and yellow.
NOTE:
The earth wire should be about 2 cm longer
than the live and neutral wires.
6) Secure the cable by means of the clamp
screws and refit the back protective screen.
The cooker should be connected to a double pole switch
with a minimum gap of 3 mm. between the switch
contacts and of a type suitable for the required load in
compliance with the current electric regulations. The
switch should be sited within 2m of the hob and be easily
accessible upon completion of the installation.
The switch must not break the yellow and green earth
cable at any point.
Ensure that the hob supply cord does not come
into contact with surfaces with temperatures
higher than 50 deg. C.
Supply Cable Specifications
Connection Min. size
Cable / flex Fuse
via
Cable/flex type
• Cooker
6 mm
2
H05 VV-F
30 A
Control
Circuit
For Uk use only
For Europe use only
Min. size Cable/flex Cable / flex type Fuse
3x 2.5 mm
2
H05 RR-F
30 A
H05V2V2-F
)
FO 2375