background image

17

OVERALL DIMENSIONS

Width:

860 mm

Depth:

510 mm

CUT OUT DIMENSIONS

Width:

830 mm

Depth:

480 mm

SUPPLY CONNECTIONS

Gas:

R 1/2 inch (1/2 inch male) Rear right hand corner

Electric:

220 V 50 Hz supply, 3 core flexible cable with non
rewireable plug.

Rear Left Burner (semi rapid)

Heat Input

2.0 kW

Front Left Burner (auxiliary)

Heat Input

1.0 kW

Rear Right Burner (semi rapid)

Heat Input

2.0 kW

Front Right Burner (rapid)

Heat Input

3.0 kW

Central Burner (Ultra-rapid Triple-crown)

Heat Input

4.0 kW

Burner

Dia. Tap By-pass

1/100 mm

Auxiliary

28

Semi-rapid

32

Rapid

40

Ultra-rapid

56

Aeration adjustment none

Instructions for the Installer

Engineers technical data

APPLIANCE CLASS

 : 3

APPLIANCE GAS SUPPLY

: gas G28-30 / 37mbar

BURNER

RAPID

SEMI-RAPID

AUXILIARY

(large)

(medium)

(small)

POSITION

MAX

MIN

MAX

MIN

MAX

MIN

MAX

MIN

 NOMINAL THERMAL
 POWER               kW

3.0

0.65

2.0

0.45

1.0

0.33

4.0

1.2

 NOMINAL FLOW
 RATE                  m

3

/h

0.286

0.062

0.190

0.043

0.095

0.031

0.381

0.114

 NOZZLE REFERENCE

119

Adjust.

96

Adjust.

70

Adjust.

146

Adjust.

 NOMINAL THERMAL
 POWER               kW

2.8

0.65

2.0

0.45

1.0

0.33

4.0

1.2

 NOMINAL FLOW
 RATE                  g/h

202

47

144

32

72

24

288

86

 NOZZLE REFERENCE

86

40

71

32

50

28

98

56

NATURAL GAS

20 mbar

TYPE OF

GAS

CHARACTERISTICS

LPG GAS

28-30/37 mbar

1/100 mm

1/100 mm

VALUE = 49.92 MJ/Kg

VALUE = 37.78 MJ/m

3

Ws - 50.7 MJ/ m

3

ULTRA-RAPID

(triple-crown)

Summary of Contents for ZGF 98

Page 1: ......

Page 2: ...can cause an accident by tipping or spillage z Never leave the hob unattended when cooking with oil and fats z Never use plastic or aluminium foil dishes on the hob z Perishable food plastic items and areosols may be affected by heat and should not be stored above or below the hob unit Service z This hob should only be repaired or serviced by an authorised Service Engineer and only genuine approve...

Page 3: ...ription of the Hob Important Safety Information 12 Description of the Hob 13 Operation 14 Maintenance and Cleaning 15 Something Not Working 16 Service and original spare parts 16 Instructions for the Installer 17 Important safety requirements 18 Installation 19 Conversion from LPG to Natural Gas 19 Commissioning 20 Electrical connections 20 Building In 21 1 AuxiliaryBurner 2 Semi rapidBurners 3 Ul...

Page 4: ...uld only use pots and pans with a flat bottom fitting the size of the burner used see table Burner minimum maximum diameter diameter Ultra rapid triple crown 180 mm 260 mm Large rapid 180 mm 260 mm Medium semi rapid 120 mm 220 mm Small auxiliary 80 mm 160 mm If you use a saucepan which is smaller than the recommended size the flame will spread beyond the bottom of the vessel causing the handle to ...

Page 5: ...r A well moistenedsoapimpregnatedsteelwoolpadcanbeused with caution if the marks are particularly difficult to remove After cleaning be sure to wipe dry with a soft cloth Ignition electrode The electric ignition is obtained through a ceramic and metal electrode Fig 1 letter C Keep these components very clean to avoid lighting difficulties and check that the burner crown holes are not obstructed Ca...

Page 6: ...it will be necessary to provide proof of purchase for any in guarantee service calls In guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown Service and original spare parts This machine before leaving the factory has been tested and studied by many experts and specialists in order to give...

Page 7: ...0 Ultra rapid 56 Aerationadjustmentnone Instructions for the Installer Engineers technical data APPLIANCE CLASS 3 APPLIANCE GAS SUPPLY gas G28 30 37mbar BURNER RAPID SEMI RAPID AUXILIARY large medium small POSITION MAX MIN MAX MIN MAX MIN MAX MIN NOMINALTHERMAL POWER kW 3 0 0 65 2 0 0 45 1 0 0 33 4 0 1 2 NOMINALFLOW RATE m3 h 0 286 0 062 0 190 0 043 0 095 0 031 0 381 0 114 NOZZLE REFERENCE 119 Adj...

Page 8: ...ceeds 11 m3 no air vent is required However if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3 If there are other fuel burning appliances in the same room should be consulted to determine the requisite air vent requirements Location The hob may be located in a kitchen a kitchen diner or bed sitting room but not in a bathr...

Page 9: ... to the hob connecting pipe Failure to ensure the correct assembly will cause leakage of gas FO 0814 FO 0264 Conversion from LPG to Natural Gas IMPORTANT The replacement conversion of the gas hob should only be undertaken by a competent person It is important to note that this model is designed for use with LPG gas but can be converted for use with Natural gas providing the correct injectors are f...

Page 10: ... supplies Electrical connections Neutral Earth yellow green The appliance is designed to be connected to 220 V monophase electricity supply The connection must be carried out in compliance with the laws and regulations in force Before the appliance is connected 1 checkthatthemainfuseandthedomesticinstallation can support the load see the rating label 2 check that the power supply is properly earth...

Page 11: ... removable to allow easy access if technical assistance is needed The space behind the kitchen unit b can be used for connections 1 FO 2563 2 Fitting the Hob into the worktop Carry out the building in of the hob as follows place the seals supplied with the hob on the side edges of the cut out and at 8 mm from the front and rear edges as shown in the diagram taking care that the seals meet without ...

Page 12: ......

Page 13: ......

Page 14: ...Grafiche MDM Forlì 35692 6601 AM 05 06 ...